• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 01:49:57 on November 2, 2001

    Entry number 75600

    keyword=End_of_Run_1434
    ****************************
     Run Number: 1434
     End of Run Comment:
    Run_type=production,beam_energy=4.627,beam_raster=off,comment_text=CW 100uA,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=74.82,target_name=H2O,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=114   ps2=16   ps3=2400   ps4=240   ps5=1   ps8=65535   
    
    EVENTS[0]: 1500232      [+]: 738474       [-]: 733518       
    TIME  [0]: 50.360 mins  [+]: 24.707 mins  [-]: 24.709 mins  
    LIVE  [0]:  94.99%      [+]:  94.94%      [-]:  95.02%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :81.2/9262.2 Hz   T2[0] :42.0/672.6 Hz   T3[0] :95.5/229229.7 Hz   T4[0] :54.4/13049.3 Hz   T5[0] :249.5/249.5 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :81.4/9279.1 Hz   T2[+] :42.1/673.2 Hz   T3[+] :95.7/229631.7 Hz   T4[+] :54.5/13074.0 Hz   T5[+] :251.1/251.1 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :81.1/9244.4 Hz   T2[-] :42.0/672.0 Hz   T3[-] :95.3/228816.8 Hz   T4[-] :54.3/13024.0 Hz   T5[-] :248.0/248.0 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 245496/27986592  T2[0] : 127013/2032213  T3[0] : 288600/692640541  T4[0] : 164291/39429897  T5[0] : 753833/753833   T8[0] :     47/3094119  
    T1[+] : 120663/13755599  T2[+] :  62370/997922   T3[+] : 141838/340412147  T4[+] :  80755/19381239  T5[+] : 372180/372180   T8[+] :     23/1518005  
    T1[-] : 120222/13705369  T2[-] :  62271/996347   T3[-] : 141347/339234911  T4[-] :  80453/19308852  T5[-] : 367656/367656   T8[-] :     23/1518143  
    
    AVERAGE CURRENT
    BCM x1 : 94.3743uA  BCM x3 : 94.6052uA  BCM x10: -35.7814uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1705 ppm     BCM u3 :     1662 ppm     BCM u10:    727.5 ppm     
    BCM d1 :     1704 ppm     BCM d3 :     1630 ppm     BCM d10:      850 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.2818         BCM u3 [0]:0.2833         BCM u10[0]:-0.1157        
    BCM u1 [+]:0.1385         BCM u3 [+]:0.1392         BCM u10[+]:0.1117         
    BCM u1 [-]:0.138          BCM u3 [-]:0.1388         BCM u10[-]:0.1115         
    
    BCM d1 [0]:0.2885         BCM d3 [0]:0.2884         BCM d10[0]:-0.1005        
    BCM d1 [+]:0.1418         BCM d3 [+]:0.1417         BCM d10[+]:0.1164         
    BCM d1 [-]:0.1413         BCM d3 [-]:0.1413         BCM d10[-]:0.1162         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1434 at Fri Nov 2 01:49:50 EST 2001
    Right Arm D1 momentum : 1.06608
    Right Arm arm angle : 74.8198
    Left Arm D1 momentum : 4.12098
    Left Arm arm angle : 12.4998
    Tiefenbach Hall A energy : 4617.95
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.675
    Right Arm Q1 momentum : 1.06615
    Right Arm Q1 gauss meter : 0.020185
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.837
    Right Arm Q2 momentum : 1.06615
    Right Arm Q2 gauss meter : -0.2419
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.869
    Right Arm D1 momentum : 1.06608
    Right Arm D1 NMR : 0.39561
    Right Arm Q3 power supply current : 424.307
    Right Arm Q3 momentum : 1.06634
    Right Arm Q3 gauss meter : -0.19042
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.48
    Left Arm Q1 momentum : 4.12116
    Left Arm Q1 gauss meter : -0.26177
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.34
    Left Arm Q2 momentum : 4.12063
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1568.44
    Left Arm D1 momentum : 4.12098
    Left Arm D1 NMR : 1.52679
    Left Arm Q3 power supply current : 1640.71
    Left Arm Q3 momentum : 4.12115
    Left Arm Q3 gauss meter : -0.8206
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 99.9375
    Current on Unser monitor : 105.86
    Current on Upstream bcm : 99.4593
    Current on Downstream bcm : 100.416
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 99.9797
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.95
    Tiefenbach Hall C energy : 3479.75
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.00475669
    IPM1H04A.XPOS : -0.178884
    IPM1H04A.YPOS : 0.00638243
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3554.5
    Waterfall Flow Meter : 4.44005
    Waterfall Tachometer : 1272.37
    Waterfall Encoder : 1.8016
    Right Arm Arm Collimator : 0.865381
    Left Arm Arm Collimator : 0.868799
    HacR_HPE1313A:0_Ch58 : -0.491211
    HacR_HPE1313A:0_Ch55 : 23.9746
    HacR_HPE1313A:0_Ch54 : -0.737793
    HacR_alignROLL : -0.25558
    HacR_alignPITCH : -0.0619585
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.202148
    HacL_HPE1313A:0_Ch55 : 25.7812
    HacL_HPE1313A:0_Ch54 : 0.0957031
    HacL_alignROLL : 0.282195
    HacL_alignPITCH : 0.114898
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.86543
    Left Arm Arm Collimator : 0.86875
    OTR x-position : -1.01516
    OTR y-position : -3.43242
    OTR x-width : 0.179958
    OTR y-width : 0.154461
    OTR data valid flag : Yes
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3554.5
    Waterfall Flow Meter : 4.39895
    Waterfall Tachometer : 1274.54
    Waterfall Encoder : 1.8017