• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name LeRose

    Log entry time 16:09:10 on November 5,2001

    Entry number 76009

    keyword=day shift summary

    0820: beam off for 10 minutes
    0830: end C-, move to D-
    0841: trigger efficiency for D-
    0845: start D-. Reduce beam to 70 uA
    1315: end D-, move to I-
    1340: trigger efficiency at I-. Very high rates. 6k in T5
    1400: controlled acces for trigger work (Michaels)
    1425: Left Q1 trip. Helium level reads negative. 5 minutes later the level started to rise and by 1435 it returned to normal. Stevens entered hall to check it out.
    1550: Michaels and Bodo finished. New trigger downloaded. Reduced current to 50 uA (T5 ~ 1.7 k) and repeating trigger efficiency.

    ======================================
    D- kinematics
    run Q(uA-hr) comment
    1584 16.8
    1585 16.8
    1586 17.2
    1587 17.2
    1588 17.4
    1589 17.2
    1590 17.3
    1591 17.3
    1592 17.4
    1593 17.5
    1594 17.3
    1595 17.4
    1596 17.2
    1597 17.4
    1598 17.2 end
    =================================
    I- kinematics
    run Q comment
    1599 trigger efficiency
    1600 JUNK
    1601 JUNK
    1602 trigger efficiency at 50 uA
    1603 JUNK
    1604 started production