     Run Number: 2027
     End of Run Comment:
    Run_type=production,beam_energy=4.627,beam_raster=off,comment_text=H- KINEMATICS.  Current 60uA.,2000/100/2200/248/1/ ps settings,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=37.616,target_name=H2O,target_type=Waterfall
    STARTING H- KINEMATICS
    
    PRESCALE FACTORS:ps1=2000   ps2=100   ps3=2200   ps4=248   ps5=1   ps8=65535   
    
    EVENTS[0]: 1354445      [+]: 663557       [-]: 666260       
    TIME  [0]: 14.105 mins  [+]: 6.924 mins  [-]: 6.926 mins  
    LIVE  [0]:  83.64%      [+]:  83.45%      [-]:  83.70%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :106.8/213609.3 Hz   T2[0] :45.1/4505.5 Hz   T3[0] :65.1/143204.3 Hz   T4[0] :31.7/7855.2 Hz   T5[0] :1664.8/1664.8 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :106.6/213273.7 Hz   T2[+] :45.0/4498.1 Hz   T3[+] :65.0/142935.1 Hz   T4[+] :31.6/7839.9 Hz   T5[+] :1665.7/1665.7 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :107.0/213945.5 Hz   T2[-] :45.1/4513.3 Hz   T3[-] :65.2/143467.2 Hz   T4[-] :31.7/7868.2 Hz   T5[-] :1666.6/1666.6 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  90391/180783523  T2[0] :  38131/3813141  T3[0] :  55089/121197853  T4[0] :  26806/6648089  T5[0] :1408982/1408982  T8[0] :     13/866640   
    T1[+] :  44303/88607525  T2[+] :  18688/1868809  T3[+] :  26992/59384356  T4[+] :  13133/3257176  T5[+] : 692048/692048   T8[+] :      6/425435   
    T1[-] :  44451/88903753  T2[-] :  18754/1875462  T3[-] :  27098/59616912  T4[-] :  13183/3269578  T5[-] : 692548/692548   T8[-] :      6/425517   
    
    AVERAGE CURRENT
    BCM x1 : 59.2359uA  BCM x3 : 59.4077uA  BCM x10: 58.5471uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1491 ppm     BCM u3 :    -1452 ppm     BCM u10:    -1207 ppm     
    BCM d1 :    -1491 ppm     BCM d3 :    -1420 ppm     BCM d10:    -1230 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04957        BCM u3 [0]:0.04983        BCM u10[0]:0.04904        
    BCM u1 [+]:0.0243         BCM u3 [+]:0.02443        BCM u10[+]:0.02405        
    BCM u1 [-]:0.02437        BCM u3 [-]:0.0245         BCM u10[-]:0.02411        
    
    BCM d1 [0]:0.0507         BCM d3 [0]:0.05072        BCM d10[0]:0.05006        
    BCM d1 [+]:0.02485        BCM d3 [+]:0.02487        BCM d10[+]:0.02454        
    BCM d1 [-]:0.02493        BCM d3 [-]:0.02494        BCM d10[-]:0.02461        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2027 at Sun Nov 11 10:55:03 EST 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 32.9492
    Left Arm D1 momentum : 4.121
    Left Arm arm angle : 12.5004
    Tiefenbach Hall A energy : 4617.92
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.43
    Right Arm Q1 momentum : 1.06582
    Right Arm Q1 gauss meter : 0.020171
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.702
    Right Arm Q2 momentum : 1.06584
    Right Arm Q2 gauss meter : -0.24125
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.012
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.297
    Right Arm Q3 momentum : 1.06632
    Right Arm Q3 gauss meter : -0.18996
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.58
    Left Arm Q1 momentum : 4.12129
    Left Arm Q1 gauss meter : -0.26183
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.8
    Left Arm Q2 momentum : 4.12168
    Left Arm Q2 gauss meter : 0.9337
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.55
    Left Arm D1 momentum : 4.12101
    Left Arm D1 NMR : 1.5268
    Left Arm Q3 power supply current : 1640.81
    Left Arm Q3 momentum : 4.12142
    Left Arm Q3 gauss meter : -0.8206
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 59.0648
    Current on Unser monitor : 64.9664
    Current on Upstream bcm : 58.7255
    Current on Downstream bcm : 59.4041
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 58.6694
    MBSY1c Hall A Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.92
    Tiefenbach Hall C energy : 3479.25
    Delta(E)/E width (MV_AI_DXWID) : 28.0859
    IPM1C12.XPOS : -0.00735867
    IPM1H04A.XPOS : -0.244749
    IPM1H04A.YPOS : -0.115897
    IPM1H04B.XPOS : -0.00320781
    IPM1H04B.YPOS : -0.00580022
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3589
    Waterfall Flow Meter : 4.10375
    Waterfall Tachometer : 1298.23
    Waterfall Encoder : 1.77817
    Right Arm Arm Collimator : 0.865479
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.517578
    HacR_HPE1313A:0_Ch55 : 24.1211
    HacR_HPE1313A:0_Ch54 : -0.792969
    HacR_alignROLL : -0.309232
    HacR_alignPITCH : -0.0378364
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.211426
    HacL_HPE1313A:0_Ch55 : 25.8789
    HacL_HPE1313A:0_Ch54 : 0.0610352
    HacL_alignROLL : 0.249783
    HacL_alignPITCH : 0.107177
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865527
    Left Arm Arm Collimator : 0.868799
    OTR x-position : 0.0722516
    OTR y-position : -0.19774
    OTR x-width : 0.151047
    OTR y-width : 0.3304
    OTR data valid flag : Yes
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3589
    Waterfall Flow Meter : 4.12804
    Waterfall Tachometer : 1259.56
    Waterfall Encoder : 1.77788