• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:54:16 on November 13, 2001

    Entry number 77133

    keyword=End_of_Run_2121
    ****************************
     Run Number: 2121
     End of Run Comment:
    Run_type=cosmics,beam_energy=4.627,beam_raster=off,comment_text=,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=79.49,target_name=H2O,target_type=Waterfall
     test of daq
    
    PRESCALE FACTORS:ps1=63   ps2=13   ps3=2450   ps4=280   ps5=1   ps8=65535   
    
    EVENTS[0]: 160          [+]: 83           [-]: 76           
    TIME  [0]: 0.491 mins  [+]: 0.241 mins  [-]: 0.241 mins  
    LIVE  [0]:  99.38%      [+]: 100.00%      [-]: 102.70%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.2/10.9 Hz   T2[0] : 1.2/15.5 Hz   T3[0] : 0.0/11.5 Hz   T4[0] : 0.0/12.0 Hz   T5[0] : 4.1/4.1  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 0.1/11.5 Hz   T2[+] : 1.2/15.7 Hz   T3[+] : 0.0/12.1 Hz   T4[+] : 0.0/11.4 Hz   T5[+] : 4.4/4.4  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 0.1/10.7 Hz   T2[-] : 1.1/15.1 Hz   T3[-] : 0.0/11.0 Hz   T4[-] : 0.0/12.9 Hz   T5[-] : 3.9/3.9  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      5/322      T2[0] :     35/456      T3[0] :      0/339      T4[0] :      1/355      T5[0] :    120/120      T8[0] :      0/30189    
    T1[+] :      2/166      T2[+] :     17/228      T3[+] :      0/175      T4[+] :      0/165      T5[+] :     64/64       T8[+] :      0/14837    
    T1[-] :      2/154      T2[-] :     16/218      T3[-] :      0/159      T4[-] :      0/186      T5[-] :     56/56       T8[-] :      0/14804    
    
    AVERAGE CURRENT
    BCM x1 : 0.0088 uA  BCM x3 : 0.0226 uA  BCM x10: 0.0363 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -77.96 ppm     BCM u3 :2.511E+04 ppm     BCM u10:    548.9 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :     4474 ppm     BCM d10:     2653 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:7.402E-07      BCM u3 [0]:2.197E-07      BCM u10[0]:9.486E-07      
    BCM u1 [+]:3.553E-07      BCM u3 [+]:1.12E-07       BCM u10[+]:4.667E-07      
    BCM u1 [-]:3.546E-07      BCM u3 [-]:1.063E-07      BCM u10[-]:4.652E-07      
    
    BCM d1 [0]:-2.189E-07     BCM d3 [0]:1.113E-06      BCM d10[0]:1.192E-06      
    BCM d1 [+]:-1.088E-07     BCM d3 [+]:5.519E-07      BCM d10[+]:5.895E-07      
    BCM d1 [-]:-1.124E-07     BCM d3 [-]:5.458E-07      BCM d10[-]:5.851E-07      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2121 at Tue Nov 13 09:54:08 EST 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 79.4901
    Left Arm D1 momentum : 4.121
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4617.92
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.5
    Right Arm Q1 momentum : 1.06592
    Right Arm Q1 gauss meter : 0.020183
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.864
    Right Arm Q2 momentum : 1.06622
    Right Arm Q2 gauss meter : -0.24127
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 365.998
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.395581
    Right Arm Q3 power supply current : 424.102
    Right Arm Q3 momentum : 1.06583
    Right Arm Q3 gauss meter : -0.18988
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.48
    Left Arm Q1 momentum : 4.12116
    Left Arm Q1 gauss meter : -0.26174
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.6
    Left Arm Q2 momentum : 4.12122
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.57
    Left Arm D1 momentum : 4.121
    Left Arm D1 NMR : 1.5268
    Left Arm Q3 power supply current : 1640.53
    Left Arm Q3 momentum : 4.12071
    Left Arm Q3 gauss meter : -0.8206
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0652452
    Current on Unser monitor : 7.36688
    Current on Upstream bcm : 0.0623033
    Current on Downstream bcm : 0.0681872
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 4627.35
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.92
    Tiefenbach Hall C energy : 3479.24
    Delta(E)/E width (MV_AI_DXWID) : 8.32693
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3589
    Waterfall Flow Meter : 4.14486
    Waterfall Tachometer : 1282.28
    Waterfall Encoder : 1.77043
    Right Arm Arm Collimator : 0.865527
    Left Arm Arm Collimator : 0.868848
    HacR_HPE1313A:0_Ch58 : -0.492676
    HacR_HPE1313A:0_Ch55 : 24.2188
    HacR_HPE1313A:0_Ch54 : -0.687012
    HacR_alignROLL : -0.202551
    HacR_alignPITCH : -0.0617792
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.206055
    HacL_HPE1313A:0_Ch55 : 25.9766
    HacL_HPE1313A:0_Ch54 : 0.0869141
    HacL_alignROLL : 0.274135
    HacL_alignPITCH : 0.112132
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865527
    Left Arm Arm Collimator : 0.868799
    OTR x-position : -0.107554
    OTR y-position : 0.844195
    OTR x-width : 0.566014
    OTR y-width : 1.23927
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3589
    Waterfall Flow Meter : 4.19904
    Waterfall Tachometer : 1264.15
    Waterfall Encoder : 1.77014