• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 07:51:37 on December 7, 2001

    Entry number 78902

    keyword=End_of_Run_2907
    ****************************
     Run Number: 2907
     End of Run Comment:
    Run_type=production,beam_energy=4.627,beam_raster=off,comment_text=production run G2-,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=0.916,rightarm_theta=37.62,target_name=H2O,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=2850   ps2=120   ps3=1780   ps4=205   ps5=1   ps8=65535   
    
    EVENTS[0]: 2706772      [+]: 1329133      [-]: 1326592      
    TIME  [0]: 22.188 mins  [+]: 10.887 mins  [-]: 10.887 mins  
    LIVE  [0]:  78.40%      [+]:  78.20%      [-]:  78.50%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :91.8/261490.8 Hz   T2[0] :45.8/5500.2 Hz   T3[0] :90.9/161727.9 Hz   T4[0] :43.6/8939.5 Hz   T5[0] :2321.4/2321.4 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :91.8/261714.3 Hz   T2[+] :45.9/5507.1 Hz   T3[+] :90.9/161884.8 Hz   T4[+] :43.7/8953.3 Hz   T5[+] :2329.7/2329.7 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :91.7/261209.3 Hz   T2[-] :45.8/5492.1 Hz   T3[-] :90.7/161528.3 Hz   T4[-] :43.5/8923.4 Hz   T5[-] :2315.4/2315.4 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 122144/348112149  T2[0] :  61018/7322246  T3[0] : 120956/215301890  T4[0] :  58052/11900772  T5[0] :3090440/3090440  T8[0] :     20/1363210  
    T1[+] :  59983/170954382  T2[+] :  29977/3597307  T3[+] :  59407/105744782  T4[+] :  28528/5848374  T5[+] :1521777/1521777  T8[+] :     10/668887   
    T1[-] :  59869/170627087  T2[-] :  29896/3587549  T3[-] :  59277/105513478  T4[-] :  28433/5828957  T5[-] :1512488/1512488  T8[-] :     10/668897   
    
    AVERAGE CURRENT
    BCM x1 : 70.1025uA  BCM x3 : 70.2859uA  BCM x10: 62.0432uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1069 ppm     BCM u3 :     1042 ppm     BCM u10:    790.6 ppm     
    BCM d1 :     1069 ppm     BCM d3 :     1020 ppm     BCM d10:    141.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.09108        BCM u3 [0]:0.09156        BCM u10[0]:0.08709        
    BCM u1 [+]:0.04473        BCM u3 [+]:0.04497        BCM u10[+]:0.04276        
    BCM u1 [-]:0.04464        BCM u3 [-]:0.04488        BCM u10[-]:0.0427         
    
    BCM d1 [0]:0.09557        BCM d3 [0]:0.09558        BCM d10[0]:0.07811        
    BCM d1 [+]:0.04694        BCM d3 [+]:0.04694        BCM d10[+]:0.03833        
    BCM d1 [-]:0.04684        BCM d3 [-]:0.04685        BCM d10[-]:0.03832        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2907 at Fri Dec 7 07:51:25 EST 2001
    Right Arm D1 momentum : 0.915998
    Right Arm arm angle : 37.6192
    Left Arm D1 momentum : 4.12093
    Left Arm arm angle : 12.5003
    Tiefenbach Hall A energy : 4617.9
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Top VDC Current : -20.0684
    Right Arm Bottom VDC Current : -18.5059
    Left Arm Top VDC Current : -7.27539
    Left Arm Bottom VDC Current : -13.3301
    Right Arm Q1 power supply current : 688.8
    Right Arm Q1 momentum : 0.916037
    Right Arm Q1 gauss meter : 0.017405
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 394.41
    Right Arm Q2 momentum : 0.916115
    Right Arm Q2 gauss meter : -0.2081
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 313.548
    Right Arm D1 momentum : 0.915998
    Right Arm D1 NMR : 0.339916
    Right Arm Q3 power supply current : 364.646
    Right Arm Q3 momentum : 0.916406
    Right Arm Q3 gauss meter : -0.16374
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.51
    Left Arm Q1 momentum : 4.1212
    Left Arm Q1 gauss meter : -0.26184
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.53
    Left Arm Q2 momentum : 4.12108
    Left Arm Q2 gauss meter : 0.9337
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.29
    Left Arm D1 momentum : 4.12093
    Left Arm D1 NMR : 1.52678
    Left Arm Q3 power supply current : 1640.76
    Left Arm Q3 momentum : 4.12102
    Left Arm Q3 gauss meter : -0.8207
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 69.5069
    Current on Unser monitor : 76.2202
    Current on Upstream bcm : 69.2505
    Current on Downstream bcm : 69.7634
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 70.2833
    MBSY1c Hall A Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.9
    Tiefenbach Hall C energy : 3479.55
    Delta(E)/E width (MV_AI_DXWID) : 1.75364
    IPM1C12.XPOS : 0.0047954
    IPM1H04A.XPOS : 0.459401
    IPM1H04A.YPOS : 0.0660292
    IPM1H04B.XPOS : -0.0603982
    IPM1H04B.YPOS : 0.0594068
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3566
    Waterfall Flow Meter : 3.95616
    Waterfall Tachometer : 1306.2
    Waterfall Encoder : 1.71122
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868457
    HacR_HPE1313A:0_Ch58 : -0.538086
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.931641
    HacR_alignROLL : -0.45199
    HacR_alignPITCH : -0.0166786
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.223633
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : 0.0712891
    HacL_alignROLL : 0.255166
    HacL_alignPITCH : 0.0921657
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868506
    OTR x-position : -7.9589
    OTR y-position : 7.73516
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : Yes
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3566
    Waterfall Flow Meter : 3.92066
    Waterfall Tachometer : 1312.25
    Waterfall Encoder : 1.70965