• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:20:59 on December 7, 2001

    Entry number 78948

    keyword=Start_Run_2936,Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=rich tests, HV scan,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=0.916,rightarm_theta=37.62,target_name=BeO,target_type=Waterfall
    Beginning-of-run EPICS data for Run Number 2936 at Fri Dec 7 14:20:52 EST 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; 
    ps1=65535,ps2=65535,ps3=4,ps4=65535,ps5=65535,ps8=65535
    
     
    Right Arm Q1 power supply current : 688.905
    Right Arm Q1 momentum : 0.916176
    Right Arm Q1 gauss meter : 0.017389
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 394.377
    Right Arm Q2 momentum : 0.916373
    Right Arm Q2 gauss meter : -0.2081
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 313.554
    Right Arm D1 momentum : 0.915999
    Right Arm D1 NMR : 0.339916
    Right Arm Q3 power supply current : 364.461
    Right Arm Q3 momentum : 0.916566
    Right Arm Q3 gauss meter : -0.16375
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.51
    Left Arm Q1 momentum : 4.12116
    Left Arm Q1 gauss meter : -0.26181
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.55
    Left Arm Q2 momentum : 4.12111
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.31
    Left Arm D1 momentum : 4.12093
    Left Arm D1 NMR : 1.52678
    Left Arm Q3 power supply current : 1640.81
    Left Arm Q3 momentum : 4.12142
    Left Arm Q3 gauss meter : -0.8207
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 5.23569
    Current on Unser monitor : 12.4574
    Current on Upstream bcm : 5.21757
    Current on Downstream bcm : 5.24062
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 5.37034
    Tiefenbach Hall A energy : 4617.89
    Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    Arc1 dp/p : 2.4507e-05
    Arc2 dp/p : -0.00143574
    Waterfall Step Motor Position :
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.118638
    Waterfall Tachometer : 1.25063
    Waterfall Encoder : 1.14572
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.868408
    HacR_HPE1313A:0_Ch58 : -0.536621
    HacR_HPE1313A:0_Ch55 : 21.582
    HacR_HPE1313A:0_Ch54 : -0.932129
    HacR_alignROLL : -0.453634
    HacR_alignPITCH : -0.0169279
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.223633
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 : 0.0712891
    HacL_alignROLL : 0.254466
    HacL_alignPITCH : 0.0919469
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 37.5
    Right Arm Angle Vernier : -13.5
    Right Arm Scattering Angle : 37.6192
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.5003
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1