Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 01:09:30 on December 10, 2001
Entry number 79280
keyword=Start_Run_3094,Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=dont use S0, but T3 and T5 are starting rich readout,new pedestal(4sig),daq_mode=both HRS daq,leftarm_p=2.070,leftarm_theta=12.500,rightarm_p=2.300,rightarm_theta=12.68,target_name=Carbon,target_type=Carbon (thick)
Beginning-of-run EPICS data for Run Number 3094 at Mon Dec 10 01:09:25 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=640,ps2=50,ps3=500,ps4=100,ps5=1,ps8=65535
Right Arm Q1 power supply current : 1729.49
Right Arm Q1 momentum : 2.30005
Right Arm Q1 gauss meter : -0.04304
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 989.764
Right Arm Q2 momentum : 2.29981
Right Arm Q2 gauss meter : 0.52
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 806.68
Right Arm D1 momentum : 2.3
Right Arm D1 NMR : 0.853502
Right Arm Q3 power supply current : 915.143
Right Arm Q3 momentum : 2.29988
Right Arm Q3 gauss meter : 0.4106
Right Arm Q3 power supply polarity : disabled
Left Arm Q1 power supply current : 1557.29
Left Arm Q1 momentum : 2.06995
Left Arm Q1 gauss meter : 0.1322
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 891.13
Left Arm Q2 momentum : 2.06951
Left Arm Q2 gauss meter : -0.4697
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 704.284
Left Arm D1 momentum : 2.07
Left Arm D1 NMR : 0.765955
Left Arm Q3 power supply current : 824.113
Left Arm Q3 momentum : 2.07002
Left Arm Q3 gauss meter : -0.4124
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 10.1419
Current on Unser monitor : 18.1305
Current on Upstream bcm : 10.0959
Current on Downstream bcm : 10.1879
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 10.3015
Tiefenbach Hall A energy : 4617.89
Beam energy : 4627.35
MBSY1c magnet current (amp) : 193.029
Arc1 dp/p : 9.18595e-06
Arc2 dp/p : -0.00142166
Waterfall Step Motor Position : 350016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.126111
Waterfall Tachometer : -1.64981
Waterfall Encoder : 1.04241
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868506
HacR_HPE1313A:0_Ch58 : -0.552246
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.864258
HacR_alignROLL : -0.384369
HacR_alignPITCH : -0.00379914
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.199219
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : 0.0239258
HacL_alignROLL : 0.210398
HacL_alignPITCH : 0.114289
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -3.3
Right Arm Scattering Angle : 12.678
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.501
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1