• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 06:53:31 on December 10, 2001

    Entry number 79302

    keyword=Start_Run_3102,Run_type=other,beam_energy=4.620,beam_raster=off,comment_text=using S0, only T5s are starting rich readout,new pedestal(4sig),daq_mode=both HRS daq,leftarm_p=2.070,leftarm_theta=12.500,rightarm_p=2.300,rightarm_theta=12.68,target_name=Carbon,target_type=Carbon (thick)
    Beginning-of-run EPICS data for Run Number 3102 at Mon Dec 10 06:53:25 EST 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; 
    ps1=6400,ps2=40,ps3=960,ps4=100,ps5=1,ps8=65535 
    Right Arm Q1 power supply current : 1729.49
    Right Arm Q1 momentum : 2.30005
    Right Arm Q1 gauss meter : -0.04306
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 989.823
    Right Arm Q2 momentum : 2.29995
    Right Arm Q2 gauss meter : 0.52
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 806.681
    Right Arm D1 momentum : 2.3
    Right Arm D1 NMR : 0.853502
    Right Arm Q3 power supply current : 914.984
    Right Arm Q3 momentum : 2.29948
    Right Arm Q3 gauss meter : 0.4105
    Right Arm Q3 power supply polarity : disabled
    Left Arm Q1 power supply current : 1557.29
    Left Arm Q1 momentum : 2.06995
    Left Arm Q1 gauss meter : 0.13219
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 891.359
    Left Arm Q2 momentum : 2.07004
    Left Arm Q2 gauss meter : -0.4697
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 704.303
    Left Arm D1 momentum : 2.07
    Left Arm D1 NMR : 0.765957
    Left Arm Q3 power supply current : 824.106
    Left Arm Q3 momentum : 2.07
    Left Arm Q3 gauss meter : -0.4125
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 20.2201
    Current on Unser monitor : 27.9404
    Current on Upstream bcm : 20.2623
    Current on Downstream bcm : 20.1778
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 20.4339
    Tiefenbach Hall A energy : 4617.9
    Beam energy : 4627.35
    MBSY1c magnet current (amp) : 193.029
    Arc1 dp/p : -2.86446e-05
    Arc2 dp/p : -0.00143748
    Waterfall Step Motor Position : 350016
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.103691
    Waterfall Tachometer : -0.199588
    Waterfall Encoder : 1.04015
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868555
    HacR_HPE1313A:0_Ch58 : -0.55127
    HacR_HPE1313A:0_Ch55 : 21.6797
    HacR_HPE1313A:0_Ch54 : -0.865723
    HacR_alignROLL : -0.386075
    HacR_alignPITCH : -0.00353462
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.200195
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : 0.0234375
    HacL_alignROLL :
    HacL_alignPITCH : 0.113122
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -3.3
    Right Arm Scattering Angle : 12.678
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.501
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1