• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:00:07 on February 4, 2002

    Entry number 81786

    keyword=Start_Run_2075,Run_type=production,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=LH2+radiator, magnet ON, veto OFF,daq_mode=coincidence,leftarm_p=2.772,leftarm_theta=32.66,photonarm_D=14.5,photonarm_angle=26.0,photonarm_p=1000,target_name=LH2,target_type=15LH2R
    Beginning-of-run EPICS data for Run Number 2075 at Mon Feb 4 20:39:49 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the calorimeter singles based on summers
    ; PS2 for the cosmic trigger for calorimeter 
    ; PS3 for the Left spectrometer based on T3 - S1+S2
    ; PS4 for the Left spectrometer redundant trigger S1+S2 or
    ;                        based on S1+S0 or S2+S0
    ; PS5 for Coinc. trigger based on S0 and Calo
    ; PS6 for laser 
    ; PS7 for the Left spectrometer based on S0, timed with calorimeter
    ; PS8 for pulser 
    ps1=10000,ps2=100000,ps3=10,ps4=20,ps5=1,ps6=1,ps7=100,ps8=1024
     
    Left Arm Q1 power supply current : 2085.69
    Left Arm Q1 momentum : 2.7723
    Left Arm Q1 gauss meter : 0.176941
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1193.49
    Left Arm Q2 momentum : 2.7717
    Left Arm Q2 gauss meter : -0.6284
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 963.083
    Left Arm D1 momentum : 2.772
    Left Arm D1 NMR : 1.02624
    Left Arm Q3 power supply current : 1103.61
    Left Arm Q3 momentum : 2.77207
    Left Arm Q3 gauss meter : 0.5525
    Left Arm Q3 power supply polarity : 0
    Left Arm Top VDC Current : -1.26953
    Left Arm Bottom VDC Current : -1.70898
    Average current of the two cavities : 15.4925
    Current on Unser monitor : 21.7999
    Current on Upstream bcm : 15.4611
    Current on Downstream bcm : 15.7055
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 15.8381
    Tiefenbach Hall A energy : 5754.14
    Tiefenbach Hall C energy : 5754.03
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 5766.18
    MBSY3c Hall C Beam energy : 5770.08
    MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 241.051
    MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 1.43896e+06
    Arc1 dp/p : 7.19565e-05
    Arc2 dp/p : -0.00138362
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.149902
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.214844
    HacL_alignROLL : 0.143464
    HacL_alignPITCH : -0.110548
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 32.5
    Left Arm Angle Vernier : 59.5
    Left Arm Scattering Angle : 32.6639
    IPM1C12.XPOS : 0.00761244
    IPM1C12.YPOS : 0.0629578
    IPM1H04A.XPOS : 0.791192
    IPM1H04A.YPOS : 0.686869
    IPM1H04B.XPOS : -2.07253
    IPM1H04B.YPOS :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Beam Half-wave plate (off=out) :
    Target OTR x-position : -1.56111
    Target OTR y-position : 1.89218
    Target OTR x-width : 0.782661
    Target OTR y-width : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 0.690806
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.735682
    Arc OTR y-position : 0.255444
    Arc OTR x-width : 4.40133
    Arc OTR y-width : 3.54558
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407