• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:09:28 on May 2, 2002

    Entry number 2413

    keyword=End_of_Run_1161
    ****************************
     Run Number: 1161
     End of Run Comment:
    Run_type=elastic,beam_energy=2.260,beam_raster=on,comment_text=Delta scan +2%; 4cm liquid hydrogen target; current ~ 20 uA,daq_mode=both HRS daq,leftarm_p=1.958,leftarm_theta=22.166,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=1.958,rightarm_theta=22.166,target_name=4cm LH2,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=5   ps2=100   ps3=5   ps4=1   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 644780       [+]: 316188       [-]: 316641       
    TIME  [0]: 10.038 mins  [+]: 4.927 mins  [-]: 4.926 mins  
    LIVE  [0]:  22.59%      [+]:  22.57%      [-]:  22.61%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :2326.1/11630.3 Hz   T2[0] :187.3/18733.0 Hz   T3[0] :2081.5/10407.4 Hz   T4[0] :121.4/121.4 Hz   T5[0] :22.5/22.5 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :2326.4/11631.9 Hz   T2[+] :187.1/18715.0 Hz   T3[+] :2081.4/10406.8 Hz   T4[+] :121.5/121.5 Hz   T5[+] :22.6/22.6 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :2326.0/11629.8 Hz   T2[-] :187.5/18753.2 Hz   T3[-] :2081.8/10408.8 Hz   T4[-] :121.2/121.2 Hz   T5[-] :22.5/22.5 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1400916/7004583  T2[0] : 112823/11282347  T3[0] :1253619/6268098  T4[0] :  73143/73143    T5[0] :  13555/13555    T8[0] :      9/616726   
    T1[+] : 687685/3438426  T2[+] :  55322/5532232  T3[+] : 615256/3076284  T4[+] :  35928/35928    T5[+] :   6688/6688     T8[+] :      4/302698   
    T1[-] : 687442/3437210  T2[-] :  55425/5542533  T3[-] : 615265/3076326  T4[-] :  35833/35833    T5[-] :   6644/6644     T8[-] :      4/302645   
    
    AVERAGE CURRENT
    BCM x1 : 17.6643uA  BCM x3 : 17.7106uA  BCM x10: 17.7164uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -299.4 ppm     BCM u3 :   -301.1 ppm     BCM u10:   -307.1 ppm     
    BCM d1 :   -298.4 ppm     BCM d3 :   -295.5 ppm     BCM d10:   -305.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01042        BCM u3 [0]:0.01045        BCM u10[0]:0.01048        
    BCM u1 [+]:0.005112       BCM u3 [+]:0.005127       BCM u10[+]:0.00514        
    BCM u1 [-]:0.005114       BCM u3 [-]:0.00513        BCM u10[-]:0.005142       
    
    BCM d1 [0]:0.01086        BCM d3 [0]:0.01088        BCM d10[0]:0.01086        
    BCM d1 [+]:0.005329       BCM d3 [+]:0.005341       BCM d10[+]:0.005331       
    BCM d1 [-]:0.005331       BCM d3 [-]:0.005343       BCM d10[-]:0.005334       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1161 at Thu May 2 19:09:17 EDT 2002
    Left Arm D1 momentum : 1.95799
    Left Arm arm angle : 22.1654
    Right Arm D1 momentum : 1.958
    Right Arm arm angle : 22.1682
    Tiefenbach Hall A energy : 2259.91
    Left Arm arm mispointing (HPT) : -0
    Right Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.88086
    Left Arm Bottom VDC Current : 1.12305
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Left Arm Q1 power supply current : 1473.05
    Left Arm Q1 momentum : 1.95797
    Left Arm Q1 gauss meter : -0.12446
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 843.194
    Left Arm Q2 momentum : 1.95818
    Left Arm Q2 gauss meter : 0.4447
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 663.698
    Left Arm D1 momentum : 1.958
    Left Arm D1 NMR : 0.724536
    Left Arm Q3 power supply current : 779.485
    Left Arm Q3 momentum : 1.95792
    Left Arm Q3 gauss meter : -0.3902
    Left Arm Q3 power supply polarity : 1
    Right Arm Q1 power supply current : 1472.28
    Right Arm Q1 momentum : 1.95798
    Right Arm Q1 gauss meter : -0.03656
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 842.664
    Right Arm Q2 momentum : 1.95801
    Right Arm Q2 gauss meter : 0.4427
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 679.639
    Right Arm D1 momentum : 1.958
    Right Arm D1 NMR : 0.726589
    Right Arm Q3 power supply current : 779.232
    Right Arm Q3 momentum : 1.95832
    Right Arm Q3 gauss meter : 0.3497
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0329922
    Current on Unser monitor : 5.36776
    Current on Upstream bcm : 0.0385546
    Current on Downstream bcm : 0.0274298
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 2262.69
    MBSY1c magnet current (amp) : 94.162
    MBSY1c Bdl : 564657
    MBSY3c Hall C Beam energy : 5582.95
    Tiefenbach Hall A energy : 2259.91
    Tiefenbach Hall C energy : 5564.65
    Delta(E)/E width (MV_AI_DXWID) : 17.605
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0.00749144
    IPM1H04B.YPOS : -0.0393191
    Left Arm Collimator : 0.615479
    Left LVDT HPM : 1566
    Left LVDT VPM : 450
    HacL_HPE1313A:0_Ch58 : -0.13623
    HacL_HPE1313A:0_Ch55 : 22.7539
    HacL_HPE1313A:0_Ch54 : -0.153809
    HacL_alignROLL : 0.197588
    HacL_alignPITCH : -0.122523
    HacL_alignHPT : -0
    Right Arm Collimator : 0.611963
    Right LVDT HPM : 999
    Right LVDT VPM : 128
    HacR_HPE1313A:0_Ch58 : -0.539551
    HacR_HPE1313A:0_Ch55 : 21.5332
    HacR_HPE1313A:0_Ch54 : -0.849609
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Wien angle : -70.2265
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -1636.3
    Wien field : 46.79
    Laser attenuation Hall A : 150
    Laser power Hall A : 60
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -5.5589
    Target OTR y-position : 7.08516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : -1.2116
    Arc OTR y-position : 0.0174825
    Arc OTR x-width : 2.94585
    Arc OTR y-width : 2.9473
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0