    User name a-onl

    Log entry time 03:14:11 on May 4, 2002

    Entry number 2537

    keyword=Start_Run_1215,Run_type=elastic,beam_energy=2.260,beam_raster=on,comment_text=Target Luminosity Scan,6msr Coll,4 cm LH2, I=5uA,daq_mode=both HRS daq,leftarm_p=1.920,leftarm_theta=22.166,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=1.920,rightarm_theta=22.166,target_name=,target_type=4cm Hydrogen
    Beginning-of-run EPICS data for Run Number 1215 at Sat May 4 03:13:51 EDT 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the Right spectrometer based on T1 defined by S1*S2
    ; PS2 for the Right spectrometer based on T2 defined by S1*S0+S2*S0
    ; PS3 for the Left spectrometer based on T3 defined by S1*S2
    ; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
    ; PS5 for coincidence of T1 and T3.
    ; PS7 irrelevant
    ; PS8 for pulser 
    ps1=6,ps2=800,ps3=6,ps4=50,ps5=1,ps6=65535,ps7=65535,ps8=65535
     
    Left Arm Q1 power supply current : 1444.45
    Left Arm Q1 momentum : 1.91996
    Left Arm Q1 gauss meter : -0.1221
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 826.744
    Left Arm Q2 momentum : 1.91998
    Left Arm Q2 gauss meter : 0.4361
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 649.943
    Left Arm D1 momentum : 1.91999
    Left Arm D1 NMR : 0.710482
    Left Arm Q3 power supply current : 764.368
    Left Arm Q3 momentum : 1.91995
    Left Arm Q3 gauss meter : -0.3824
    Left Arm Q3 power supply polarity : 1
    Right Arm Q1 power supply current : 1443.75
    Right Arm Q1 momentum : 1.92005
    Right Arm Q1 gauss meter : -0.03588
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 826.363
    Right Arm Q2 momentum : 1.92013
    Right Arm Q2 gauss meter : 0.4343
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 664.945
    Right Arm D1 momentum : 1.92
    Right Arm D1 NMR : 0.712488
    Right Arm Q3 power supply current : 764.067
    Right Arm Q3 momentum : 1.92021
    Right Arm Q3 gauss meter : 0.3429
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : -0.390625
    Left Arm Bottom VDC Current : 2.00195
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Average current of the two cavities : 4.9689
    Current on Unser monitor : 9.91631
    Current on Upstream bcm : 4.96958
    Current on Downstream bcm : 4.96821
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 5.00786
    Tiefenbach Hall A energy : 2259.86
    Tiefenbach Hall C energy : 5564.65
    Delta(E)/E width (MV_AI_DXWID) : 16.8501
    MBSY1c Hall A Beam energy : 2262.69
    MBSY3c Hall C Beam energy : 5582.95
    MBSY1c magnet current (amp) : 94.162
    MBSY1c Bdl : 564657
    Arc1 dp/p : 0.000110923
    Arc2 dp/p : -0.00148434
    Left Arm Arm Collimator : 0.615527
    Left LVDT HPM : -487
    Left LVDT VPM : 542
    HacL_HPE1313A:0_Ch58 : -0.13623
    HacL_HPE1313A:0_Ch55 : 22.5586
    HacL_HPE1313A:0_Ch54 : -0.153809
    HacL_alignROLL : 0.197
    HacL_alignPITCH : -0.121065
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 22.5
    Left Arm Angle Vernier : -27
    Left Arm Scattering Angle : 22.1654
    Right Arm Arm Collimator : 0.612061
    Right LVDT HPM : 1002
    Right LVDT VPM : 240
    HacR_HPE1313A:0_Ch58 : -0.539551
    HacR_HPE1313A:0_Ch55 : 21.3867
    HacR_HPE1313A:0_Ch54 : -0.853027
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Right Arm Angle Floor Angle : 22
    Right Arm Angle Vernier : -5
    Right Arm Scattering Angle : 22.1682
    IPM1C12.XPOS : 0.269154
    IPM1C12.YPOS : -0.0729571
    IPM1H04A.XPOS : 0.0843493
    IPM1H04A.YPOS : 0.282031
    IPM1H04B.XPOS : 0.457272
    IPM1H04B.YPOS : 0.000243032
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -70.2265
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -1636.3
    Wien field : 46.79
    Laser attenuation Hall A : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 62
    Laser power Hall A : 60
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 3.22055
    Target OTR y-position : 0.192898
    Target OTR x-width : 0.485832
    Target OTR y-width : 0.320845
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : 1.09883
    Arc OTR y-position : -3.46006
    Arc OTR x-width : 2.1693
    Arc OTR y-width : 1.8923
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0