NEXT
User name a-onl
Log entry time 20:24:14 on May 13, 2002
Entry number 3398
keyword=End_of_Run_1559
****************************
Run Number: 1559
End of Run Comment:
Run_type=coincidence,beam_energy=3.36,beam_raster=on,comment_text=LH2 4cm coinc,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=20.257,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=-1.1771,rightarm_theta=61.184,target_name=LH2,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=1 ps2=100 ps3=1 ps4=1 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 993408 [+]: 487112 [-]: 486489
TIME [0]: 46.149 mins [+]: 22.620 mins [-]: 22.620 mins
LIVE [0]: 90.21% [+]: 90.24% [-]: 90.18%
TRIGGER RATES: PRES/REAL
T1[0] :28.5/28.5 Hz T2[0] :65.7/6566.6 Hz T3[0] :190.8/190.8 Hz T4[0] :107.7/107.7 Hz T5[0] : 5.0/5.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :28.6/28.6 Hz T2[+] :65.7/6567.6 Hz T3[+] :191.1/191.1 Hz T4[+] :107.4/107.4 Hz T5[+] : 5.0/5.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :28.4/28.4 Hz T2[-] :65.7/6566.2 Hz T3[-] :190.5/190.5 Hz T4[-] :108.0/108.0 Hz T5[-] : 5.0/5.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 78848/78848 T2[0] : 181826/18182661 T3[0] : 528447/528447 T4[0] : 298289/298289 T5[0] : 13779/13779 T8[0] : 43/2835402
T1[+] : 38795/38795 T2[+] : 89136/8913630 T3[+] : 259400/259400 T4[+] : 145733/145733 T5[+] : 6730/6730 T8[+] : 21/1389776
T1[-] : 38538/38538 T2[-] : 89116/8911678 T3[-] : 258488/258488 T4[-] : 146544/146544 T5[-] : 6780/6780 T8[-] : 21/1389768
AVERAGE CURRENT
BCM x1 : 56.6336uA BCM x3 : 56.7643uA BCM x10: 50.6962uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 373.7 ppm BCM u3 : 358.9 ppm BCM u10: 275.3 ppm
BCM d1 : 375.5 ppm BCM d3 : 350.3 ppm BCM d10: 80.69 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1531 BCM u3 [0]:0.1539 BCM u10[0]:0.1461
BCM u1 [+]:0.07509 BCM u3 [+]:0.07545 BCM u10[+]:0.07165
BCM u1 [-]:0.07504 BCM u3 [-]:0.07539 BCM u10[-]:0.07161
BCM d1 [0]:0.1605 BCM d3 [0]:0.1605 BCM d10[0]:0.1346
BCM d1 [+]:0.0787 BCM d3 [+]:0.0787 BCM d10[+]:0.06599
BCM d1 [-]:0.07864 BCM d3 [-]:0.07864 BCM d10[-]:0.06598
****************************
End-of-run EPICS data for Run Number 1559 at Mon May 13 20:24:02 EDT 2002
Left Arm D1 momentum : 2.979
Left Arm arm angle : 20.2566
Right Arm D1 momentum : 1.17702
Right Arm arm angle : 61.184
Tiefenbach Hall A energy : 3358.66
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -2.58789
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 2241.33
Left Arm Q1 momentum : 2.97918
Left Arm Q1 gauss meter : 0.18989
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1282.86
Left Arm Q2 momentum : 2.97924
Left Arm Q2 gauss meter : -0.675
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1042.55
Left Arm D1 momentum : 2.979
Left Arm D1 NMR : 1.10305
Left Arm Q3 power supply current : 1186.07
Left Arm Q3 momentum : 2.97918
Left Arm Q3 gauss meter : 0.5935
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 885.08
Right Arm Q1 momentum : 1.17707
Right Arm Q1 gauss meter : -0.022053
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 506.72
Right Arm Q2 momentum : 1.17741
Right Arm Q2 gauss meter : 0.2662
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 404.182
Right Arm D1 momentum : 1.17702
Right Arm D1 NMR : 0.436778
Right Arm Q3 power supply current : 468.397
Right Arm Q3 momentum : 1.17715
Right Arm Q3 gauss meter : 0.21
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 0.0341336
Current on Unser monitor : 4.21177
Current on Upstream bcm : 0.0399889
Current on Downstream bcm : 0.027816
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 3363.97
MBSY1c magnet current (amp) : 140.095
MBSY1c Bdl : 839483
MBSY3c Hall C Beam energy : 5582.94
Tiefenbach Hall A energy : 3358.66
Tiefenbach Hall C energy : 5565.99
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : -0.0208557
IPM1H04B.YPOS : -0.0296321
Left Arm Collimator : 0.61543
Left LVDT HPM : -685
Left LVDT VPM : 951
HacL_HPE1313A:0_Ch58 : -0.133301
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.102051
HacL_alignROLL : 0.245364
HacL_alignPITCH : -0.125682
HacL_alignHPT : -0
Right Arm Collimator : 0.612012
Right LVDT HPM : 387
Right LVDT VPM : 660
HacR_HPE1313A:0_Ch58 : -0.492676
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.836914
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 12.4959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 307.42
Wien field : 8.2213
Laser attenuation Hall A : 100
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -5.5589
Target OTR y-position : 7.08516
Target OTR x-width : 0
Target OTR y-width : 0.822778
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -1.21201
Arc OTR y-position : -0.312413
Arc OTR x-width : 2.94719
Arc OTR y-width : 2.9702
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0