    User name R. Michaels

    Log entry time 00:54:17 on June15,2002

    Entry number 86042

    keyword=spot size adjust, start prod

    Adjusting the width of the spot with raster off

    HARP scan.......CODA run........Widths at 4B from analysis
    .........................................................X...............Y.....microns
    1786...................1492.....................91..............223
    1787.....repeat.......same result
    MCC makes adjustment.
    1788.....................none...................93..............191
    MCC makes adjustment.
    1789....................1493....................106............172
    Try "one more time".
    1790....................1494.....................111...........154
    We decide to run with this spot size.

    BEAM position from EPICS
    IPM1H04A.XPOS 0.810649
    IPM1H04A.YPOS 1.02345
    IPM1H04B.XPOS -0.0226329
    IPM1H04B.YPOS 0.0357602


    Next, we put in LD2 target and take production data for kinematics Q2D_c20
    Note, the MCC can only deliver 50 microamps with stable beam; therefore,
    the current scan which requires 100+ uA is abandoned for now.