• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name RS & BM

    Log entry time 02:31:54 on June16,2002

    Entry number 86119

    This entry is a followup to: 86062

    keyword=PZT & IA Test (part 2)

    23:30 Start the test:

    *Here are the initial values:
    IGLdac3:ao_0 = 5.0 ..... (PZT X)
    IGLdac3:ao_1 = 5.0 ..... (PZT Y)
    IGLdac3:ao_3 = 1.0 ..... (IA)

    I =50 uA, Beam Energy = 4712.9 MeV
    Charge FB=ON, Position FB=ON (from the accelerator status,
    from the data file: both are OFF).

    10,000 pairs each run

    Error on charge asymmetry~16 ppm
    Error on position differences ~ 150 nm

    Parity DAQ:

    Run# ........ X......Y......IA.......BCM1.....BCM2.....4ax.....4ay.....4bx....4by
    ...................V.......V......V..........ppm........ppm........nm.....nm.....nm.....nm
    1196 .........5.0......5.0....1........ 0284.......0287.......557...-1561...437...-939
    1197 .........5.0......5.0....1........ 0060.......0062.......522...-1070...359...-852
    1198 .........5.0......5.0....1........ 0171.......0172.......389...-1223...208...-872
    1199 .........9.0......5.0....1........ 0096.......0096.......967...-2241..1039...-1335
    (4 beam trips)
    1200.....No beam
    ......................................................................................................................

    No Beam for a while. DO THE TEST LATER.
    Set IGLdac3:ao_0 = 5V
    Set IGLdac3:ao_1 =5 V
    Set IGLdac3:ao_3 =1 V

    The setup values as before.
    ------------------------------