    User name Reitz

    Log entry time 18:52:22 on June20,2002

    Entry number 86517

    keyword=EP beam energy

    EP energy measurement:

    a) rate vs current scan:

    I (uA) Rate (Hz)
    2.65 0.0881
    4.00 0.141
    6.00 0.49

    => decided to take data at 4 uA

    2) ep run 3192: 60 min at 4uA, beam rock steady, BPM reading did not change
    even in the last digit, 3 beam trips ,
    besides the poor statistics ( which are even distributed over two microstrips)
    it is a good measurement.

    3.) beam energy (average over both detectors:)

    4.70400 GeV +- 0.492 MeV (stat) +- 1.03 MeV (sys)

    details of the results:
    *****************
    RESULTS All triggers Electron detector 6
    Number of elastic evts 8 Number of elastic combi 11
    Coplanarity Cut (mm) 0 0 Coplanarity Average 0 mm
    Energy Cut (MeV) 0 0
    x beam position (mm) -0.165907
    Measured Energy
    4.7035 GeV +- 0.388909 MeV (stat) +- 1.03 MeV (sys) - RMS (MeV) 1.26723
    *****************
    RESULTS All triggers Electron detector 7
    Number of elastic evts 5 Number of elastic combi 6
    Coplanarity Cut (mm) 0 0 Coplanarity Average 0 mm
    Energy Cut (MeV) 0 0
    x beam position (mm) -0.105532
    Measured Energy
    4.70481 GeV +- 0.491935 MeV (stat) +- 1.03 MeV (sys) - RMS (MeV) 0.582678
    *****************