• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name moffit

    Log entry time 13:07:04 on October21,2002

    Entry number 88632

    keyword=Parity Target Boiling Test

    Boiling Studies ala Parity Daq

    Oversampling=13, RampDelay=0, IntegrateTime=980
    DacNoise ON.

    1836 ... 200k ... LH2..108uA.. (DacNoise OFF) (HV -925V, -950V)
    1837 ... 280k ... DacNoise Calibration Run (HV off)
    1838..................DacNoise ON, HV OFF, No Beam. Oversampling=1, Low Gain
    1839..................DacNoise ON, HV -1000,-1000, No Beam. Oversampling=1, Low Gain
    1840..................DacNoise ON, HV -1000,-1000, No Beam. Oversampling=1, Low Gain
    1841..................DacNoise ON, HV -1000,-1000, No Beam. Oversampling=13, High Gain
    1842..................DacNoise ON, HV OFF, No Beam. Oversampling=13, High Gain
    1843..................DacNoise ON, HV -900,-900, No Beam. Oversampling=13, High Gain
    1844..................DacNoise ON, HV -950,-950, No Beam. Oversampling=13, High Gain
    1845..................DacNoise ON, HV -900,-900, No Beam. Oversampling=1, Low Gain
    1846..................DacNoise ON, HV -950,-950, No Beam. Oversampling=1, Low Gain
    1847..................DacNoise ON, HV -925,-925, No Beam. Oversampling=1, Low Gain (BEAM ON around 7k)
    1848 junk
    1849..................DacNoise ON, HV -925,-925, No Beam. Oversampling=13, High Gain
    1850..................DacNoise ON, HV -925,-925, No Beam. Oversampling=13, High Gain (more events)
    1851..................DacNoise ON, HV -925,-925, No Beam. Oversampling=13, High Gain (more events)