• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Suleiman

    Log entry time 23:09:08 on October21,2002

    Entry number 88699

    keyword=Parity Target Boiling Test

    Boiling Studies ala Parity Daq
    DacNoise ON.

    Raster 2.8X2.8 (set Value) (Measured 4X4)

    15 cm LH2:

    1926...30uA..OS=13..HG..HV1=-975..HV2=-1000
    1927...30uA..OS=1..LG..HV1=-975..HV2=-1000 (lumi saturated)
    1928...30uA..OS=1..LG..HV1=-900..HV2=-925


    4 cm LH2
    1929...100uA..OS=1..LG..HV1=-900..HV2=-925
    1930...100uA..OS=13..HG..HV1=-900..HV2=-925
    1931...100uA..OS=3..LG..HV1=-900..HV2=-925
    1932...100uA..OS=1..LG..HV1=-900..HV2=-925

    15 cm Al Dummy
    1933...30uA..OS=1..LG..HV1=-900..HV2=-925
    1934...30uA..OS=13..HG..HV1=-900..HV2=-925
    1935...30uA..OS=13..HG..HV1=-950..HV2=-975
    1936...30uA..OS=13..HG..HV1=-1000..HV2=-1025

    15 cm LD2
    1937...1uA..OS=13..HG..HV1=-1000..HV2=-1025
    1938...1uA..OS=1..LG..HV1=-1000..HV2=-1025
    1939...4uA..OS=1..LG..HV1=-1000..HV2=-1025