    User name a-onl

    Log entry time 15:21:11 on October 22, 2002

    Entry number 88793

    keyword=End_of_Run_2677
    ****************************
     Run Number: 2677
     End of Run Comment:
    Run_type=other,beam_energy=5.009,beam_raster=off,comment_text=Beam 5 uA, raster on to check,daq_mode=Coinc (buffered),kin_name=Q3_d20,leftarm_p=2750.7,leftarm_theta=29.197,rightarm_p=3028.3,rightarm_theta=30.612,target_type=15cm LD2
     
    
    PRESCALE FACTORS:ps1=8   ps2=20   ps3=20   ps4=40   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 13922        [+]: 4204         [-]: 4295         
    TIME  [0]: 4.938 mins  [+]: 2.427 mins  [-]: 2.426 mins  
    LIVE  [0]: 257.24%      [+]: 158.16%      [-]: 161.16%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 5.0/40.1 Hz   T2[0] : 2.2/43.2 Hz   T3[0] : 5.2/103.3 Hz   T4[0] : 1.9/77.8 Hz   T5[0] : 4.0/4.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 5.1/40.5 Hz   T2[+] : 2.2/43.3 Hz   T3[+] : 5.2/103.3 Hz   T4[+] : 1.9/76.5 Hz   T5[+] : 4.0/4.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 5.0/39.7 Hz   T2[-] : 2.2/43.2 Hz   T3[-] : 5.2/103.6 Hz   T4[-] : 2.0/79.3 Hz   T5[-] : 4.0/4.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   1483/11871    T2[0] :    639/12795    T3[0] :   1530/30613    T4[0] :    576/23059    T5[0] :   1180/1180     T8[0] :      4/303364   
    T1[+] :    736/5894     T2[+] :    315/6303     T3[+] :    751/15039    T4[+] :    278/11140    T5[+] :    576/576      T8[+] :      2/149088   
    T1[-] :    722/5781     T2[-] :    314/6292     T3[-] :    754/15083    T4[-] :    288/11542    T5[-] :    585/585      T8[-] :      2/149039   
    
    AVERAGE CURRENT
    BCM x1 : 4.9886 uA  BCM x3 : 4.9715 uA  BCM x10: 4.9732 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -7125 ppm     BCM u3 :    -7281 ppm     BCM u10:    -7254 ppm     
    BCM d1 :    -7154 ppm     BCM d3 :    -7337 ppm     BCM d10:    -7261 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001487       BCM u3 [0]:0.001479       BCM u10[0]:0.001479       
    BCM u1 [+]:0.0007273      BCM u3 [+]:0.0007232      BCM u10[+]:0.0007234      
    BCM u1 [-]:0.0007375      BCM u3 [-]:0.0007335      BCM u10[-]:0.0007337      
    
    BCM d1 [0]:0.001469       BCM d3 [0]:0.001467       BCM d10[0]:0.001468       
    BCM d1 [+]:0.0007184      BCM d3 [+]:0.0007174      BCM d10[+]:0.0007178      
    BCM d1 [-]:0.0007285      BCM d3 [-]:0.0007278      BCM d10[-]:0.000728       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2677 at Tue Oct 22 15:20:43 EDT 2002
    Left Arm D1 momentum : 2.75069
    Left Arm arm angle : 29.1971
    Right Arm D1 momentum : 3.02829
    Right Arm arm angle : 30.612
    Tiefenbach Hall A energy : 5009.02
    Left Arm arm mispointing (HPT) :
    Right Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 4.15039
    Left Arm Bottom VDC Current : -2.09961
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Left Arm Q1 power supply current :
    Left Arm Q1 momentum : 2.75079
    Left Arm Q1 gauss meter :
    Left Arm Q1 power supply polarity :
    Left Arm Q2 power supply current : 1184.49
    Left Arm Q2 momentum : 2.75078
    Left Arm Q2 gauss meter :
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 954.302
    Left Arm D1 momentum : 2.7507
    Left Arm D1 NMR : 1.01834
    Left Arm Q3 power supply current : 1095.16
    Left Arm Q3 momentum : 2.75084
    Left Arm Q3 gauss meter :
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 power supply current :
    Right Arm Q1 momentum : 3.02832
    Right Arm Q1 gauss meter : 0.0563
    Right Arm Q1 power supply polarity :
    Right Arm Q2 power supply current : 1303.33
    Right Arm Q2 momentum : 3.02842
    Right Arm Q2 gauss meter : -0.6849
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 1087.92
    Right Arm D1 momentum : 3.02829
    Right Arm D1 NMR : 1.12376
    Right Arm Q3 power supply current : 1205
    Right Arm Q3 momentum : 3.02834
    Right Arm Q3 gauss meter : -0.5401
    Right Arm Q3 power supply polarity : enabled
    Average current of the two cavities : 6.56594
    Current on Unser monitor : -0.784712
    Current on Upstream bcm : 6.51303
    Current on Downstream bcm : 6.61677
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 6.84702
    MBSY1c Hall A Beam energy : 5019.53
    MBSY1c magnet current (amp) : 209.525
    MBSY1c Bdl : 1.25263e+06
    MBSY3c Hall C Beam energy : 4029.98
    Tiefenbach Hall A energy : 5009.03
    Tiefenbach Hall C energy : 4018.24
    Delta(E)/E width (MV_AI_DXWID) : 3.42839
    IPM1C12.XPOS : 0.00550202
    IPM1H04A.XPOS : 0.338649
    IPM1H04A.YPOS : 0.234789
    IPM1H04B.XPOS : 0.128333
    IPM1H04B.YPOS : 0.0666402
    Left Arm Collimator : 0.871387
    Left LVDT HPM :
    Left LVDT VPM :
    HacL_HPE1313A:0_Ch58 : -0.15918
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.265137
    HacL_alignROLL :
    HacL_alignPITCH :
    HacL_alignHPT :
    Right Arm Collimator : 0.863037
    Right LVDT HPM : 4851
    Right LVDT VPM : -726
    HacR_HPE1313A:0_Ch58 : -0.530273
    HacR_HPE1313A:0_Ch55 : 22.4121
    HacR_HPE1313A:0_Ch54 : -0.787109
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Wien angle : -9.49571
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -220
    Wien field : 6.2161
    Laser attenuation Hall A : 150
    Laser power Hall A : 62
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : 8 cycles
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    Target OTR x-position : 0.894599
    Target OTR y-position : 1.67006
    Target OTR x-width : 1.40074
    Target OTR y-width : 1.37204
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -2.07738
    Arc OTR y-position : -0.0146392
    Arc OTR x-width : 2.96526
    Arc OTR y-width : 3.04182
    Arc OTR data valid flag : No
    Arc OTR In/Out : MaxPix is Bad
    fan frequency loop 1 : 33.5
    fan frequency loop 2 : 57.5
    fan frequency loop 3 : 0
    Encoder position : 5.53672e+06
    temperature loop 1 : 18.99
    temperature loop 1 : 19.19
    temperature loop 1 : 92.83
    temperature loop 2 : 21.99
    temperature loop 2 : 21.99
    temperature loop 2 : 22.08
    temperature loop 3 : 94.98
    temperature loop 3 : 94.98
    temperature loop 3 : 94.98
    pressure loop D2 : 22.5498
    pressure loop H2 : 23.3143
    FPP HV 7.1.0 of chamber 1 : 0
    FPP HV 7.1.1.of chamber 1 : 0
    FPP HV 7.1.2 of chamber 1 : 0
    FPP HV 7.1.3 of chamber 1 : 0
    FPP HV 7.1.4 of chamber 1 : 0
    FPP HV 7.1.5 of chamber 1 : 0
    FPP HV 7.1.8 of chamber 2 : 0
    FPP HV 7.1.9.of chamber 2 : 0
    FPP HV 7.1.10 of chamber 2 : 0
    FPP HV 7.1.11 of chamber 2 : 0
    FPP HV 7.1.12 of chamber 2 : 0
    FPP HV 7.1.13 of chamber 2 : 0
    FPP HV 8.1.0 of chamber 3 : 1775.3
    FPP HV 8.1.1.of chamber 3 : 1775.3
    FPP HV 8.1.2 of chamber 3 : 1775.3
    FPP HV 8.1.3 of chamber 3 : 1775.3
    FPP HV 8.1.4 of chamber 3 : 1775.3
    FPP HV 8.1.5 of chamber 3 : 1775.3
    FPP HV 8.1.8 of chamber 4 : 1774.7
    FPP HV 8.1.9.of chamber 4 : 1774.7
    FPP HV 8.1.10 of chamber 4 : 1774.7
    FPP HV 8.1.11 of chamber 4 : 1774.7
    FPP HV 8.1.12 of chamber 4 : 1774.7
    FPP HV 8.1.13 of chamber 4 : 1774.7