Main INDEX
Monthly INDEX
PREV
NEXT
User name X. Zheng
Log entry time 21:38:03 on July 1,2004
Entry number 127669
Followups:
keyword=Beam energy dithering ON, and note on how to change the freq.
21:35 Beam energy dithering was turned on with high frequency.
---*---*---*---*---*---*---*---*---*---*---*---*---*---*---*---
Note on how to change the freq. (by Kent):
To change the freq. go to the terminal for COUNTING HOUSE ROC23 (hatsv7)
change FROM HIGH TO LOW duty factor:
-type "bmw_steps_per_pause=2400", then type return;
-then check the freq by typing "bmw_steps_per_pause" and return;
change FROM LOW TO HIGH duty factor:
-type "bmw_steps_per_pause=167", then type return;
-then check the freq by typing "bmw_steps_per_pause" and return;
Note:
1/ smaller number is for high freq., larger number is for low freq.;
2/ low freq. is for normal production run;
3/ in hac terminal, "Ctrl+H" = backspace.