    Log entry time 21:38:03 on July 1,2004

    Entry number 127669

    Followups:

    keyword=Beam energy dithering ON, and note on how to change the freq.

    21:35 Beam energy dithering was turned on with high frequency.
    
    ---*---*---*---*---*---*---*---*---*---*---*---*---*---*---*---
    Note on how to change the freq. (by Kent):
    
    To change the freq. go to the terminal for COUNTING HOUSE ROC23 (hatsv7)
    
    change FROM HIGH TO LOW duty factor:
    -type "bmw_steps_per_pause=2400", then type return;
    -then check the freq by typing "bmw_steps_per_pause" and return;
    
    
    change FROM LOW TO HIGH duty factor:
    -type "bmw_steps_per_pause=167", then type return;
    -then check the freq by typing "bmw_steps_per_pause" and return;
    
    Note:
    1/ smaller number is for high freq., larger number is for low freq.;
    2/ low freq. is for normal production run;