Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 14:33:18 on September24,2004
Entry number 131865
This entry is a followup to: 131690
keyword=BCM cabling fixed
Arun & Bob: The BCM signals were fixed. The d3 on L-arm was fixed
when we re-plugged in the cables upstairs. The cable does not appear
to be bad, I suppose someone had not plugged it in all the way.
The u10 on R-arm was bad because of the RG213 cable from the Hall A
floor to the back of the detector stack. Cable #7 is bad. We sent
the signal a different route.