    Log entry time 08:09:21 on October 3,2004

    Entry number 132777

    keyword=shift summary

    00:00 start run 3031
    00:35 end run 3031

    00:36 start run 3032
    01:11 end run 3032

    01:12 bleedthrough measurement : 2.14%

    01:15 start run 3033
    01:50 end run 3033

    01:53 start run 3034
    02:26 end run 3034


    02:33 start run 3035
    02:40 end run 2035

    02:49 start run 3036

    daq problems :

    - 7 bloc of the proton array have no signal :
    channel 38 39 60 61 62 63 64
    - channel 11 and 26 is read but the ADC values look like pedestal
    call Alex to fix it
    this problem appeared from run 3024 to run 3035

    Alex fixed the first problem :
    for the run 3036 blocs 38 39 60 61 62 63 64 are read
    for bloc 11 an ARS problem is suspected : access needed to test
    for bloc 26 need to check the gain with a higher HV value

    03:40 end run 3036
    change HV of the bloc 26 of the proton array
    old HV value : -582V
    new HV value : -750V

    03:40 start run 3037
    03:46 end run 3037

    problem on bloc 26 is still here

    04:11 call MCC to have an access to check the proton array detector

    the HV channel on the crate was wrong : channel 26 is now plugged on a spare HV channel (cf dvcs ELOG entry )
    the ARS slot for the channel 11 seems to be wrong. This card need to be changed.
    channel 11 of the proton array is plugged on a spare slot of the ARS (cf halog entry)

    06:30 back to beam permit :2.5uA
    start run 3046

    channel 26 works properly (cf dvcs elog entry)
    we checked that this channel worked during older runs run 2881

    03:40 end run 3036

    06:32 start run 3046
    07:31 end run 3046

    problem of daq for runs 3046 and 3047


    07:33 start run 3048
    07:39 bleedthrough measurement :1.4%