User name a-onl
Log entry time 14:06:59 on August 2, 2005
Entry number 150444
keyword=End_of_Run_2347
****************************
Run Number: 2347
End of Run Comment:
Run_type=spot++,beam_energy=2.750,beam_raster=on,comment_text=raster check,daq_mode=twoarm,kin_name=,leftarm_p=2.737,leftarm_theta=6.0,rightarm_p=2.733,rightarm_theta=6.0,target_type=Helium
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=1 ps5=10 ps6=10 ps7=1 ps8=1
EVENTS[0]: 991395 [+]: 976559 [-]: 0
TIME [0]: 281.899 mins [+]: 277.741 mins [-]: 0.017 mins
TRIGGER RATES: PRES/REAL
T1[0] : 0.1/0.1 Hz T2[0] : 0.0/0.0 Hz T3[0] : 0.0/0.0 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] :58.6/58.6 Hz T8[0] :58.6/58.6 Hz
T1[+] : 0.1/0.1 Hz T2[+] : 0.0/0.0 Hz T3[+] : 0.0/0.0 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] :58.6/58.6 Hz T8[+] :58.6/58.6 Hz
T1[-] : 0.0/0.0 Hz T2[-] : 0.0/0.0 Hz T3[-] : 0.0/0.0 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 2239/2239 T2[0] : 0/0 T3[0] : 163/163 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 991294/991294 T8[0] : 991166/991166
T1[+] : 2239/2239 T2[+] : 0/0 T3[+] : 157/157 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 976693/976693 T8[+] : 976564/976564
T1[-] : 0/0 T2[-] : 0/0 T3[-] : 0/0 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 0/0
AVERAGE CURRENT
BCM x1 : 20.0856uA BCM x3 : 19.9791uA BCM x10: 0.1469 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.011E+06 ppm BCM u3 :1.004E+06 ppm BCM u10: 1E+39 ppm
BCM d1 :1.003E+06 ppm BCM d3 :1.003E+06 ppm BCM d10:1.115E+06 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.3399 BCM u3 [0]:0.3382 BCM u10[0]:-0.007069
BCM u1 [+]:0.3349 BCM u3 [+]:0.3333 BCM u10[+]:-0.01199
BCM u1 [-]:-1.149E-07 BCM u3 [-]:-4.003E-08 BCM u10[-]:-2.898E-08
BCM d1 [0]:0.3396 BCM d3 [0]:0.3377 BCM d10[0]:0.01204
BCM d1 [+]:0.3346 BCM d3 [+]:0.3328 BCM d10[+]:0.007126
BCM d1 [-]:-2.559E-08 BCM d3 [-]:-2.627E-08 BCM d10[-]:-2.334E-08
****************************
End-of-run EPICS data for Run Number 2347 at Tue Aug 2 14:06:53 EDT 2005
Left Arm D1 momentum : 2.737
Left Arm arm angle : 12.321
Right Arm D1 momentum : 2.733
Right Arm arm angle : 0
HALLA:p : 2753.22
HALLA:dpp : -2.07445e-05
Tiefenbach Hall A energy : 2753.22
Right Arm arm mispointing (HPT) : 0
Left Arm Top VDC Current : 0.683594
Left Arm Bottom VDC Current : 0.732422
Left septum set current : 283.75
Left septum current readback : 277.222
Left septum upper coil T : 6.739
Left septum lower coil T : 6.813
Right septum set current : 278.22
Right septum current readback : 274.414
Right septum upper coil T : 7.506
Right septum lower coil T : 6.926
Left Arm Q1 momentum : 2.73713
Left Arm Q2 power supply current : 1187.74
Left Arm Q2 momentum : 2.73704
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 951.54
Left Arm D1 momentum : 2.737
Left Arm D1 NMR : 1.01325
Left Arm Q3 power supply current : 1281.73
Left Arm Q3 momentum : 2.73705
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.733
Right Arm Q1 gauss meter : -0.04065
Right Arm Q2 power supply current : 1185.97
Right Arm Q2 momentum : 2.73297
Right Arm Q2 gauss meter : 0.6224
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 972.796
Right Arm D1 momentum : 2.73299
Right Arm D1 NMR : 1.01418
Right Arm Q3 power supply current : 1279.87
Right Arm Q3 momentum : 2.73307
Right Arm Q3 gauss meter : 0.5742
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 38.7974
Current on Unser monitor : 36.1027
Current on Upstream bcm : 38.4389
Current on Downstream bcm : 39.1558
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 58.5891
Hall C Current : 19.0162
MBSY1c Hall A Beam energy : 2757.46
MBSY1c magnet current (amp) : 114.779
MBSY1c Bdl : 688127
MBSY3c Hall C Beam energy : 1857.18
Tiefenbach Hall A energy : 2753.25
Tiefenbach Hall C energy : 1853.06
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.666031
IPM1H04A.XPOS : 1.41856
IPM1H04A.YPOS : -0.00873655
IPM1H04B.XPOS : -1.43082
IPM1H04B.YPOS : 0.010348
Left Arm Collimator : 0.0570801
HacL_HPE1313A:0_Ch58 : -0.184082
HacL_HPE1313A:0_Ch55 : 27.9297
HacL_HPE1313A:0_Ch54 : 0.027832