• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name S. Bailey

    Log entry time 08:04:55 on August 3,2005

    Entry number 150521

    keyword=Owl Shift Summary

    Owl shift summary
    Shift workers:
    S. Bailey, A. Kolarkar, Y. Prok
    
    -----------------------
    23:41 Start Production Run 4061, IHWP In, 35 uA
    00:10 Ended Compton Run 11675 (ROC1 & ROC5 stopped responding)
    00:15 Start Compton Run 11676
    00:28 I noticed that the left septum current is incorrectly set at          
    283.75 A. I changed the current to 283.57 A as instructed in          the run 
    plan.
    00:37 End Production Run 4061 - 46,209 good parity events
    00:38 Start Production Run 4062, IHWP In, 35 uA
    01:33 End Production Run 4062 - 47,285 good parity events
    -----------------------
    01:33 Start Profile Scanner Run 4063, IHWP In, 35 uA
    01:47 End Profile Scanner Run 4063 - 9,569 good parity events
    01:53 Start Profile Scanner Run 4064, IHWP In, 35 uA
          We are doing this again because I accidentally changed the            
    voltage on S2 1-10 "Left" on the last scan. This should have          been 
    "Right". This was corrected for this run. 
    02:15 End Profile Scanner Run 4064 - 10,225 good party eventd
    ------------------------
    02:16 Start Production Run 4065, IHWP In, 35 uA
    02:18 End Compton Run 11676
    02:21 Start Compton Run 11677
    02:51 Fill pressure and 4He temperature decreasing. Cut beam. Called        
    target expert on call J.P. Chen.
    02:54 End Production Run 4065 because we cut beam - 29,422 good             
    parity events
    03:04 Target conditions ok again, ask for beam back
    ------------------------
    03:06 Start Production Run 4066, IHWP In, 35 uA
    04:01 End Production Run 4066 - 47,158 good parity events
    04:01 Start Production Run 4067, IHWP In, 35 uA
    04:10 End Compton Run 11677
    04:13 Start Compton Run 11678
    04:58 End Production Run 4067 - 43,416 good parity events
    05:00 Start Production Run 4068, IHWP In, 35 uA
    05:55 End Production Run 4068 - 42,859 good parity events
    05:56 Start Production Run 4069, IHWP In, 35 uA
    06:53 End Production Run 4069 - 43,512 good parity events
    -------------------------
    06:55 Move IHWP from "IN" to "OUT"
    06:55 Start Production Run 4070, IHWP Out, 35 uA
    07:00 End Compton Run 11678
    07:00 Start Compton Run 11679
    07:51 End Production Run 4070 - 46,059 good parity events
    07:52 Start Production Run 4071, IHWP Out, 35 uA