User name R. Michaels
Log entry time 01:53:07 on August14,2005
Entry number 151807
Followups:
keyword=cavity phase study data
Starting with spectrometer run 2423 we did a series of runs
with different phase offsets on the BPM cavities #2 and #3.
Note, I think the BSY BPMs (cavity #1) X,Y output are not working.
Perhaps needs an IOC reboot ? The ones near the target are fine.
The idea of the scan in phase is to see where the raster pattern
might flatten. Going from one extreme (20% of the slider GUI
scale) to the other (80%) makes a dramatic change which is hard
to describe (distorts the spectra). Below are the runs.
Gains don't change during this.
Upstream and Downstream gains are identical.
BCM pre-gain 11, post-gain 1024
X pre-gain 9, post-gain 18000
Y same as X.
Run ......... Phases
............ Upstream Monitor ......... Downstream Monitor
............. X ....... Y ........... X ......... Y
Nominal Start Values:
2422 ........ -12764 ... 9992 ...... 14420 ..... 11084
Now we change:
2423 ........ no good
2424 ........ -24971 ... -23753 ..... -24483 .... -23509 ... 20%
2425 ........ +24240 ... +25753 ..... +27650 .... +26676 ... 80%
2426 ........ 365 ....... 852 ......... 609 ...... 1827
2427 ........ -13764 .... 8161 ....... 13277 ..... 8161
2428 ........ -12302 .... 10110 ...... 14251 ..... 10110
2429 ........ -10841 .... 11571 ...... 16200 ..... 13033
2430 ........ -9866 ..... 12059 ...... 16688 ..... 13520
2431 ........ -8892 ..... 13033 ...... 18637 ..... 15957
2432 ........ -3532 ..... 6212 ....... 19611 ..... 4263
2433 ........ -1583 ..... 4263 ....... 18637 ..... 1337
2434 ......... 852 ....... 7674 ...... 21073 ..... 2314
2435 ......... 6699 ...... 12546 ...... 2070 ..... 6699
2436 ......... 11084 ..... 15469 ...... 4506 ..... -9379
Until further analysis, here's where I leave the phases:
............. -12790 .... 9623 ...... 14251 ..... 11084