    Here is a table summarizing the data from the helicity magnet tests done 
    yesterday.  The table values are the slopes of the position differences for 
    each Hall A bpm versus the setpoint on the helicity magnets, so the units are 
    um/setpoint unit.
    
    	0L01V	0L02H	0L03V	0L03H
    
    4ax	0.037	-0.057	0.042	-0.067
    
    4ay	-0.004	0.004	-0.004	0.004
    
    4bx	-0.002	0.0004	-0.0007	0.001
    
    4by	-0.004	0.014	-0.012	0.007
    
    
    BPM 4bx is relatively insensitive to all of the magnets.  This is probably due 
    to the small jitter/beta function at 4bx.  4ax has a large response to all the 
    magnets, but changes sign between horizontal and vertical magnets.  4ay has the 
    same small response to all magnets with opposite sign between vertical and 
    horizontal magnets.  I believe that the magnets are relatively orthogonal in 
    the injector, but there must be some rotation in the hall because our x 
    position differences respond to H and V magnets as observed in 4ax.  The y 
    position differences also respond to both H and V magnets as observed by 4by.
    
    We also took some oversampling runs to look at the behavior of the helicity 
    magnets with time.  Figure 1 shows the x and y position differences at bpm 0L06 
    vs timeslot when all the magnets are on, but setpoints are at 0.  Figure 2 
    shows the response of x response of bpm0L06 for the H magnets and the y 
    response for the V magnets.  There is a big difference between the first 
    timeslot and the following timeslots for 0L03H, but all the distributions seem 
    to look fairly similar to the time dependence when the helicity magnets are not 
    being pulsed.
    