Main INDEX
Monthly INDEX
PREV
NEXT
User name hyde
Log entry time 12:30:45 on October18,2006
Entry number 187510
This entry is a followup to: 187505
keyword=HRS-R ramp down
11:34
Noticed Momentum shift in Run 1470 replay
ioc for HRS-R dipole has heartbeat, but readback values are frozen,
and epics values in start run file have error messages.
Rebooted iocha16 (hareboot25)
retyped p0=1.94430
could not regain readback/control
Rebooted NMR power (hareboot27)
Dipole control window still showed p0=1.94430
(suggestion: retype 1.94431 to tickle epics into action)
At some point, Dipole started ramping down.
12:00 regained control, dipole ramping back up from 0.64 Tesla