• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name X. Zheng

    Log entry time 16:05:29 on May 8,2007

    Entry number 201381

    keyword=day shift summary

    08:00 Problem with analyzer script, taking data w/o replaying.

    10:00 Hall C stared target cooling. We moved to Al 20cm dummy target with 40uA;

    11:15 Right Q1 helium flow starts dropping steadily, and stay between 50 and 60% for about an hour. Tech-on-call contacted the cryo group and tried to avoid tripping of our magnets;

    12:22 Hall C target cool-down completed;

    12:40 target moved to 3He;
    12:42 Run 3266 end failed. Reset TS0, restart CODA;
    12:47 105uA in the Hall;

    16:00 smooth running...

    Runs of this shift:

    3259-3262: 3He production, 105uA
    3263-3266: Al 20cm dummy, 40uA. Run 3266 had TS0 crash (end of run fail);
    3267-3273: 3He production, 105uA