    keyword=NaI detector cabling completed

    We (XinHu, Yoomin, Yi, Alexandre, Seonho and JP) completed cabling
    of the NaI detector. The HV cables are as following:
    The BNL HV crate: There are 16 slots and each has 16 channels (0-15).
    There are 3 broken channels (slot 1, ch.4; slot 1, ch. 8 and slot 2, ch. 3). The last channel (slot 16, ch. 15) was not used. The other
    252 channels are connected in order.
    The signal cable map (including rebin cable for ADCs) will be entered by Yoomin at a later time.
    We also installed a large fan for the PMTs and another fan on the crate for signal cable breakout boxes.
    All powered up (fans, HVs, crates). Checking signals now.