User name Z. Meziani
Log entry time 08:10:49 on November13,2007
Entry number 214311
keyword=Shift Summary
Shift Started
00:00-00:04
Dummy target
Run # 2255 (left) events 260K
20792(right) events
Moved target to LH2.
Alarm on LH2 target pressure.
Filling valve closed. 15psi instead of 23 psi.
Valve opened and waiting for pressure to reach 23.
00:34-00:38
target LH2
Run # 2356 (left) events
20793(right) events
Pressure at the begining and the end of LH2 runs need
to be averaged.
Moved to Pb target
01:03-01:1:09
Target Pb
Run # 2359 (left) events 317K
20796 (right) events 332K
Move target to He4
01:17-01:21
Target He4
Run # 2360 (left) events 298K
20797(right) events 284K
Changing momentum on HRSL (p0 = 574.616 MeV/c) and
HRSR (535.753 MeV/c)
01:29-01:33
Target He4, left spectrometer ready-right not yet ready.
Run # 2361 (left) events 346K
Move to Pb target
01:41-01:46
Pb target
Run# 2362 (left) events 336K
Move target to LH2
Right spectrometer momentum settled
01:52-01:57
LH2 target
Run # 2363 (left) events 364K
20798 (right) events 460K
Move to Dummy target
02:05-02:18
Target Dummy
Run # 2364 (left) events 819K
207800 (right) events 354K
Move to 12C
02:26-02:32
target 12C
Run # 2365 (left) events 236K
Move target to 56Fe
02:38 - 02:45
target 56Fe
Run # 2366 (left) events 336K
20802 (right) events 338K
Change Momentum on the left arm to 535.753 MeV/c
Move target to He4
03:07 - 3:11
target He4
Run # 2367 (left) events 523K
20803 (right) events 318K
Move target to Pb
03:21-03:26
target Pb
Run# 2368 (left) events 481K
20804 (right) events 464K
Momentum change on the right arm to 0.465.735 MeV/c
Move target to LH2
03:32-03-38
target LH2
Run # 2369 (left) events 288K
(right spec settling )
Move target to Dummy
03:44-03:50
target Dummy
Run # 2370 (left) events 415K
Move target to 12C left
04:01-04:06
target 12C
Run # 2371 (bad) events 100K
04:07-04:12
Run # 2372(good) (left) events 255K
Move target to 56Fe
04:17-04:24
target 56Fe
Run # 2373 (left) events 342K
Change the left arm momentum to 499.519 MeV/c
04:33- 04:37
Target 56Fe
Run # 2374 (left) 272K
20805 (right) 254K
Run # 2375 (left) 39K
Move target to 12C
04:46 - 04:51
target 12C
Run# 2376 (left) events 322K
20806 (right) events 310K
Move target to dummy
05:00-5:08
target dummy
Run # 2377 (left) events
20807 (right) events
Move target to LH2
05:25-05:32
target LH2
Run # 2378 (left) events 326K
20808 (right) events 289K
Move target to Pb
05:37-05:41
target Pb
Run # 2379 (left) events 292K
20809 (right) events 275K
Move target to He4
05:50-05:55
target HE4
Run # 2380 (left) events 292K
20810 (right) events 275K
Momentum chang eon both spectrometers
HRSL p0= 465.735 MeV/c
HRSR p0 = 404.867 MeV/c
06:00-6:08
Target He4
Run # 2381 (left) events 459K
right arm field settling
Move to Pb target
06:14-06:21
Run # 2382 (left) events 318K
HRSR field settling
Move to LH2 target
06:28-06:35
Run # 2383 (left) 293K
Move to Dummy target
06:43-06:52
Run # 2385 (left) 503K
Move to 12C target
07:03-07:13
Run # 2386 (left) 425K
20811 (right)430K
Move to 56Fe target
07:23-07:30
Run # 2387 (left)
20812 (right)
New momentum for the left spectrometer
HRSL = 434.236
Movin the target to He4.
07:54-07:56
He4 target
Run # 2388 (left) events
20813 (right
Moving target to Pb
Shift ends