User name X. Zheng
Log entry time 16:02:05 on November18,2007
Entry number 215362
keyword=day shift summary
08:00 waiting for beam harp scan result, both spectrometers are at the correct configuration. Compton rate looks normal (5KHz at 5uA);
9:20 beam position, size (harp), and raster are all okay now, start taking data (3 runs), but later found they are with high Compton beam.
10:10 noticed Compton rate is very high. Asked for beam retune on the empty target.
11:05 Beam is good now. Reboot right arm CODA (no event coming in);
11:15 Moved to Fe-beam-right, start production with Pleft=814.648, Pright=708.181
12:12 Change P settings to Pleft=759.552, Pright=615.628
12:17 Left arm ready
12:25-12:33 change left P to 708.181;
13:45-14:18 RF problem, beam off.
14:33-15:14 change right P to 535.170;
15:06-15:11 change left P to 660.285;
Run list:
Left arm:
Run#/ Target/ P0/ Current/ start/ stop/ comment
2602/Empty/ 815/ 5uA/ spot size check
2603/Empty/ 815/ 5uA/ spot size check
2604/Empty/ 815/ 5uA/ spot size check
2605/Fe_right/ 815/ 50uA/ high Compton count
2606/C_right/ 815/ 50uA/ high Compton count
2607/dummy/ 815/ 50uA/ high Compton count
2608-2609/ Empty/ 815/ 50uA/ spot size check
2610/ Fe_right/ 815/ 50uA/ good
2611/ C_right/ 815/ 50uA/ good
2612/ dummy/ 815/ 50uA/ good
2613/ Pb / 815/ 25uA/ good
2614/ He / 815/ 50uA/ good
2615/ He / 760/ 50uA/ good
2616/ Pb / 760/ 50uA/ good
2617/ dummy / 760/ 50uA/ good
2618/ C_right / 760/ 50uA/ good
2619/ Fe_right / 760/ 50uA/ good
2620/ He / 708/ 50uA/ good
2621/ Pb / 708/ 50uA/ good
2622/ dummy / 708/ 50uA/ good
2623/ C_right / 708/ 50uA/ good
2624/ Fe_right / 708/ 50uA/ good
2625/ Fe_right / 660/ 50uA/ good
2626/ C_right / 660/ 50uA/ good
2627/ dummy / 660/ 50uA/ good
2628/ Pb / 660/ 50uA/ good
2629/ He / 660/ 50uA/ on-going
-----------
Right arm:
-----------
Run#/ Target/ P0/ Current/ start/ stop/ comment
20954/Empty/ 708/ 5uA/ spot size check
20955/Empty/ 708/ 5uA/ spot size check
20956/Empty/ 708/ 5uA/ spot size check
20957/Fe_right/ 708/ 50uA/ high Compton count
20958/C_right/ 708/ 50uA/ high Compton count
20959/dummy/ 708/ 50uA/ high Compton count
20960-20962/ Empty/708/ 50uA/ spot size or DAQ check
20963/ Fe_right/ 708/ 50uA/ good
20964/ C_right/ 708/ 50uA/ good
20965/ dummy/ 708/ 50uA/ good
20966/ Pb/ 708/ 25uA/ good
20967/ He/ 708/ 50uA/ good
20968/ dummy/ 616/ 50uA/ good
20969/ C_right/ 616/ 50uA/ good
20970/ Fe_right/ 616/ 50uA/ good
20971/ He/ 616/ 50uA/ good
20972/ Pb/ 616/ 50uA/ good
20974/ C_right/ 535/ 50uA/ forgot to change PS
20975/ C_right/ 535/ 50uA/ good
20976/ dummy / 535/ 50uA/ good
20977/ Pb / 535/ 50uA/ good
20978/ He / 535/ 50uA/ on-going