Main INDEX
Monthly INDEX
PREV
NEXT
User name M.Olson
Log entry time 08:08:29 on January14,2008
Entry number 225358
keyword=Owl Shift Summary
OWL Shift Summary (Olson, Yan)
--------------------------------------------------------------
Run_L Run_R p0_L p0_R Tar Comments:
--------------------------------------------------------------
5029 22680 0.25349 0.25349 DUM 120 deg production
5030 22681 0.25349 0.25349 C12 (RT)
5031 22682 0.25349 0.25349 Fe (RT)
0055: Change p0_L to 0.236350 GeV/c
Change p0_R to 0.220365 GeV/c
--------------------------------------------------------------
Run_L Run_R p0_L p0_R Tar Comments:
--------------------------------------------------------------
5032 ----- 0.23635 ------- Fe (RT)
5033 ----- 0.23635 ------- C12 (RT)
5034 ----- 0.23635 ------- Dummy
5035 ----- 0.23635 ------- H2 ***Repeat, new prescales
5036 ----- 0.23635 ------- H2 ***Repeat of 5035
5037 ----- 0.23635 ------- Pb 5 uA
5038 ----- 0.23635 ------- He
0244: Change p0_L to 0.220365 GeV/c
--------------------------------------------------------------
Run_L Run_R p0_L p0_R Tar Comments:
--------------------------------------------------------------
5039 22683 0.22037 0.22037 He
5040 22684 0.22037 0.22037 Pb 20 uA
5041 22685 0.22037 0.22037 H2
5042 22686 0.22037 0.22037 Dummy
5043 22687 0.22037 0.22037 C12(RT)
5044 22688 0.22037 0.22037 Fe(RT)
0428: Change p0_L to 0.205461 GeV/c
Change p0_R to 0.191566 GeV/c
--------------------------------------------------------------
Run_L Run_R p0_L p0_R Tar Comments:
--------------------------------------------------------------
5045 ----- 0.20546 ------- Fe(RT)
5046 ----- 0.20546 ------- C12(RT)
5047 ----- 0.20546 ------- Dummy
5048 ----- 0.20546 ------- H2
5049 ----- 0.20546 ------- Pb 25 uA
5050 ----- 0.20546 ------- He
0611: Change p0_L to 0.191566 GeV/c
--------------------------------------------------------------
Run_L Run_R p0_L p0_R Tar Comments:
--------------------------------------------------------------
5051 22689 0.19157 0.19157 He
5052 22690 0.19157 0.19157 Pb
0652: MCC is setting controlled access for installation of Ozone sampling pump.
0725: Lost Loop3 temperature readout on TV monitor and half of our stripchart
temperature readouts for loop 3.
Loop 3 target heater to "manual" P = 270 W
Loop 3 VPT temperature stable at ~18.8 K
Monitoring VPT readout and adjusting heater output
**************************************************************