User name R. Michaels
Log entry time 23:44:02 on October20,2008
Entry number 244197
Followups:
keyword=attempts to fix roc4
Below is what I did to try to fix roc4 readout.
The present status is that it reads fast (76 usec deadtime)
but only with a hack (see below). I worry there may
be a serious hardware problem with this crate.
The hack: each event, first read, then ignore, the 1875 which
is presently in slot 18 (only). It would be better to read
then clear; will try that tomorrow.
Sequence of tests:
datascan indicated the 1875 in slot 25 was reporting anomolously
even if it was not in the list of modules. What I mean by
"anomolously" is that the function fb_frcm_1 indicates that
slot has a hit, and furthermore the function takes a geological
timescale to return (ca 140 msec !!).
Physically removed the TDC in slot 25 (note, I tried to recable
things but this should be checked).
Next got anom. reporting from the (different) 1875 in slot 18.
I decided to replace the scaler 1151 in the SFI since it showed
a bus error. I put in a CAEN V260 to grant the bus. Did not help.
At present the DAQ runs fast with the aforementioned hack but
on rare occasions all 3 modules report anomolously.
Fastbus test code revealed no problems with the bus or modules.