During the access today, I checked the scaler channels on L_HRS for triggers T2 , T6 and T7 that were problematic(double counting..see ref log entry). Here is the summary.
1. The signals on the ECL-NIM converter do not show any double pulse.
2. If I swap T1(good) with T2(problem) signal on the ECL-NIM converter, the scaler shows correct counts on both the triggers and consistent with BigBite (run 2268).
3. Step 2 is true when done separately with T6(run 2272) and T7(run2276) - (I always swapped with T1).
4. On the scope the signals were about 25ns wide, so.. on Brad's suggestion I increased the width to 60ns. That only fixed T7 which is now consistent with BigBite - T2 and T6 are still bad.(run 2284)
5. At this point I decided to use completely different copies of T2, T6 and T7 that I am sending to L_HRS(these are not being used..nobody knows about it anyway) on the same ribbon cable that carries other triggers. This helped fix all triggers except T2(-+) and T6(++) combination. (run 2288)
I didn't time to investigate further as target folks took over the hall for laser alignment. I'll check them later.
Below is the summary after step 5.
BBITE ------------- Scaler Summary ---------------- Scaler bank bbite clock location 4 7 clock counts 217572 clock rate 1024 Time of run 3.54 min Triggers: 1 = 117485 2 = 2656 3 = 4268 4 = 1768 5 = 2656 Accepted triggers: 101485 Accepted triggers by target and helicity state: (++) = 24351 (+-) = 24497 (-+) = 21750 (--) = 21890 Trigger 1,2,3,4,5,6,7,8 by target and helicity state : (++) (+-) (-+) (--) trig 1 27189 27313 24527 24719 trig 2 628 643 539 518 trig 3 1013 1027 861 844 trig 4 400 427 389 346 trig 5 628 643 539 518 trig 6 1579 1661 1339 1356 trig 7 628 643 539 518 trig 8 51978 51950 43214 43187 Charge Monitors (Micro Coulombs) Upstream BCM gain x1 58.38 x3 26.94 x10 -1.19 Downstream BCM gain x1 11.55 x3 2.04 x10 1.34 [adaq@adaql4 scaler]$ ./tscalntup /adaql2/data2/e06010_2288.dat.0 Left Bank = Left Opened scaler map file scaler.map
Bdate : day = 26 month = 8 year = 2008 Using Left Arm BCM pedestals Normal end of file /adaql2/data2/e06010_2288.dat.0 encountered
LEFT
------------- Scaler Summary ---------------- Scaler bank Left clock location 1 7 clock counts 208545 clock rate 1024 Time of run 3.39 min Triggers: 1 = 113784 2 = 2547 3 = 4094 4 = 1699 5 = 2547 Accepted triggers: 101484 Accepted triggers by target and helicity state: (++) = 24350 (+-) = 24497 (-+) = 21750 (--) = 21890 Trigger 1,2,3,4,5,6,7,8 by target and helicity state : (++) (+-) (-+) (--) trig 1 27188 27313 24527 24710 trig 2 628 643 1078 518 trig 3 1013 1027 861 844 trig 4 400 427 390 346 trig 5 628 643 539 518 trig 6 2227 1661 1339 1355 trig 7 628 643 539 518 trig 8 51977 51951 43214 43176 Charge Monitors (Micro Coulombs) Upstream BCM gain x1 55.96 x3 25.82 x10 -1.14 Downstream BCM gain x1 11.07 x3 1.95 x10 1.28