keyword=Target Summary during Spin flip test @ Delta Resonance & further
Summary
Spin Flip is working now:
Spin Signal is stable. Read in from DAQ is OK. Scalar seems
fine.
AFP Loss is at a steady rate of 1%(abs.) per flip for the
first 6 flips. Though
correction coil, which would reduce the loss is OFF.
Pol. Dropped from 48% -> 41% after 10 flips
One stepper motor controller error. Probably due to
communication delay. Just click
"Clear Error" to recover
Flip #31-40 = AFP Loss Test for No correction coil, 220C.
Loss = 1.6%/Flip
Flip #41-50 = AFP Loss Test for correction coil @ (Large =
0.52A; Small = 0.52A),
220C. Field started slow drifting 1% higher since flip # 39
to flip # 50, which
make the test meaningless.
Time Line
3:40 Fill N2 50 psig
3:44 call for 2uA
3:47 run 2905, N2 Dilution factor, 324K Evt
3:47 run 2906, N2 Dilution factor, 261K Evt
3:47 run 2907-2909, N2 Dilution, Alex is testing RICH
on LHRS
Wait Wait & Wait ....
5:00 The Hot wires which bring both spin signal to
logical 1 state is removed.
Spin signal to DAQ is now controlled by NMR signal.