• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name V. Sulkosky

    Log entry time 13:15:54 on November 17, 2008

    Entry number 249381

    This entry is a followup to: 249326

    keyword=Moved S2m left PMT #4 Signal to a New ADC Channel

    Unfortunately/fortunately the ADC signal for S2m PMT # 4 came back. It's
    nice that it was back, but that made trouble shooting what was causing
    the problem harder. Since run 3586, there has been a reasonable
    looking ADC signal in the channel. The TDC spectra has always been
    present.

    I checked the signal on the scope coming from the detector and also at
    the lower patch panel right before going into the ADC. The signal looks
    alive and very healthy. On a gamble, I switched the ADC channel to see
    if this problem goes away. I moved the signal from ROC 3, slot 25
    channel 20 to channel 43, which comes right after the Gas Cerenkov
    signals.

    I took a pedestal run and updated both the pedestal suppression file
    and the db_L.s2.dat file. I might need to create a new database
    directory to reflect the changes that I made today.

    A copy of this log entry has been emailed to: camsonne,rom,jiang,ycwang,bogdanw