keyword=More tests for the Lasers
Did one more laser power test for the COMET lasers to find out the real
degradation of the diode.
Jlab @ 25C
40A: 25.2W (no old data)
30A: 17.1W
20A: 9.0W
10A: 1.24W
W&M @ 26C
40A: 27.6W (was 28.6W before experiment)
30A: 18.6W
20A: 9.8W
10A: 0.98W
Rutgers @ 20C
40A: 29.1W (was 30.3W before experiment)
30A: 20.4W
20A: 11.7W
10A: 2.73W
Looks like that both the W&M and Rutgers have about 4% drop in output
power. However, because the Rutgers laser was living in a much cooler
condition than the W&M one (20C compared 26C), the life time is supposed
to be longer, so I hope that's a long term effect. We will keep an eye on
this.