Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name Chiranjib
Log entry time 19:38:58 on January 12, 2009
Entry number 255660
keyword=Internal Temperature Test ( with Al's suggestions)
Another internal temp. test is performed after discussing with Al. This
method has been applied at UVA. Since we have some time, we could afford
to loose some polarization.
Cell :: BRADY
Holding field :: Transverse -
Pumping :: -
NMR frequency sweep done on pumping chamber.
RF = longitudinal
pick up (PC) = vertical
***************************************************************
Data :: C:\HappyValentine\NMR\Data\NMR_Freq_He_20090112_191755
***************************************************************
15 NMR frequency sweeps have been done in the following order---
LASER ON ------> NMR1 , NMR2 , NMR3
LASER OFF------> NMR4 , NMR5 , NMR6
LASER ON ------> NMR7 , NMR8 , NMR9
LASER OFF------> NMR10 , NMR11 , NMR12
LASER ON ------> NMR13 , NMR14 , NMR15
The time interval between each NMR is 1 min.
A copy of this log entry has been emailed to: jpchen,yqiang