    User name A. Puckett

    Log entry time 23:55:09 on January14,2009

    Entry number 256142

    keyword=swing shift summary

    Shift workers:
    SL: Andrew Puckett
    TO: Ameya Kolarkar
    3rd: Ron Gilman

    When we took over from day shift, the hall was in controlled access to fix the RICH to try to get it back in the DAQ and to put the lumi monitors back in the DAQ as well, since it was discovered yesterday that the lumi signals were no longer in the DAQ.

    At 16:25, the access is finished and we asked to go to Beam Permit and to move the target to BeO to check the beam position on startup. We also requested 2 uA as starting beam current.

    At 16:52, we took beam on BeO for steering and spot check.

    At 17:10, we moved to the 3He target, and took several short runs at 2 uA for another spot check. At the same time, the left arm magnet and detector IOCs briefly lost communication, we decided to reboot both. The IOC reboot caused us to lose the NMR lock, so we had to power-cycle the left-arm NMR.

    At 17:27, we asked MCC for full current (13.5 uA) and took the first production run, 5158. Shortly into the run, we realized the HAPPEX DAQ was not running, so we ended run 5158 and started the HAPPEX DAQ before starting CODA run 5158.

    As of this writing, at 22:22, we have been smoothly taking production data since 17:30, getting some nice ABUs.

    As of this writing, there are six minutes remaining in the shift, and smooth data taking has continued...

    Production run summary:

    Run #, start time, stop time, charge (u3 BCM)
    5158, 17:27, 17:31, .003527, (HAPPEX DAQ not running this run)
    5159, 17:32, 18:31, .04621
    5160, 18:33, 19:36, .04622, rebooted ROC5 after the end of this run
    5161, 19:40, 20:42, .04669
    5162, 20:43, 21:43, .047
    5163, 21:45, 22:44, .04709
    5164, 22:45, 23:46, .04693
    5165, 23:50, continued into owl shift