    User name Jin

    Log entry time 17:26:40 on January 23, 2009

    Entry number 257449

    This entry is a followup to: 257447

    keyword=Re: LABVIEW CRASH

    An EPICS communication error has occurred at 17:06:43 1/23/2009. It caused the spin flip software get disconnected from IOC.

    Therefore, other parts of spin flip system, including physical target state and spin signal sent to DAQ, is still valid. The run quality should not be affected.

    The error might due to the interface software has been running for too long a time (weeks), and error gradually accumulates. Suggestion to avoid it from further happening is restart Labview each time we have chance to.

    A copy of this log entry has been emailed to: jpchen,chiran,yqiang