• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name Moffit

    Log entry time 10:39:18 on February 06, 2009

    Entry number 259192

    keyword=oddity in transversity's GUI configuration for detectorBB.cfg

    Matt just found an oddity in the detectorBB.cfg used in Transversity. The shower "y" was plotted twice, instead of showing the preshower "y".

    This is what is was:

    #Shower Hits over Blocks
    newpage 2 2
            title BB shower & Preshow block hits
            #macro shower_hit.C("BB_sh_x_y")
            BB_ps_x
            BB_sh_y
            BB_sh_x
            BB_sh_y
    

    Changing it to:

    #Shower Hits over Blocks
    newpage 2 2
            title BB shower & Preshow block hits
            #macro shower_hit.C("BB_sh_x_y")
            BB_ps_x
            BB_ps_y
            BB_sh_x
            BB_sh_y