• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name brads

    Log entry time 00:26:46 on February 13, 2009

    Entry number 260798

    keyword=OWL shift requests

    1) Please take more T6 triggers (currently 20Hz).
       - I think we should be able to take 500Hz and still have deadtimes
    below 15%.
       - Please double check the deadtimes with the BBNormAna offline code as
    well.
       - Try and take ~500Hz of T6 for all runs from now on provided it doesn't
         push the deadtime above 15%.
    
    2) Please take a single  30 minute run with a beam current of 5 uA.
       - Adjust the prescales (in both arms) to compensate for the lower current.
       - Make a halog entry titled 'Run XXXX -> 5 uA' or equivalent so I can
    find it.
    
    3) Please take a single  30 minute run with a beam current of 1 uA.
       - Adjust the prescales (in both arms) to compensate for the lower current.
       - Make a halog entry titled 'Run XXXX -> 1 uA' or equivalent so I can
    find it.
    
    


    A copy of this log entry has been emailed to: moffit