• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name Ole Hansen

    Log entry time 18:45:27 on February26,2009

    Entry number 263543

    keyword=Rastersize check

    With reference cell in (114 psig N2) at 2uA, we get the following rates:

    raster 2x2: T2=1.3 kHz, T6=13 kHz
    raster 4x3.8: T2=1.35 kHz, T6=13.4 kHz

    MCC cannot increase the raster y-size to more than 6.58 mm (->3.8 mm for us), so we skip the "6x6" mm raster setting and will take production runs at 4x3.8 mm raster size.