keyword=Missing EDTM in BigBite triggers (solved)
This is a side effect of adding the preshower to the trigger. The EDTM
signal is not fed into the preshower FI/FOs so the EDTM-T6 trigger is no
longer formed. T2 requires T6, so it isn't formed anymore either.
Unfortunately there is no simple way to feed an EDTM pulse into the
preshower circuit so we're stuck.
EDTM on T1 still works (of course). Might be worth sampling T1 (not sure
if it's worth it...).