    keyword=BB to RHRS cable connections

    Here's the connections BB to/from RHRS

    RG-58:
    Color    What
    -----------------
    Red      Target/Spin 1 (To RHRS)
    Orange   Target/Spin 2 (To RHRS)
    Yellow   Target/Spin 3 (To RHRS)
    Brown    Target/Spin 4 (To RHRS)
    Green    103.7kHz clock (To RHRS)
    Blue     ND ROC Busy (To RHRS)
    Purple   EDTM (from RHRS)
    White    L1Accept (from RHRS)
    

    RS-485: Grey banded cable is the TS-ROC connection. Other is the spare (not connected on RHRS side).

    We'll need to disconnect these cables on the RHRS before Monday morning.