Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name V. Sulkosky
Log entry time 19:22:51 on April 25, 2009
Entry number 268432
This entry is a followup to: 268034
keyword=Re: 1024 Hz clock fixed on R-HRS
I found that the eighth channel of the LeCroy 4616 was being used as a
fan out. Besides the input for the normalization scaler, one copy was
going to the PVDIS setup and the other copy I will give details on below.
I decided to remove both of these outputs. I have found in the past, that
it is best not to use all the NIM outputs on these modules as fan-outs,
hence the bad scaler clock. I sent a copy of the clock for PVDIS from the
PS 757, which is used as a fan-out. I completely removed the other copy.
More details;
The second copy of the clock was being sent to a level translator. From
this module the clock was connected back to the normalization scaler 4616
module in channel 5, which would normally be T5. I have no clue what
someone was trying to do, but they created a loop from and back to the
4616. As soon as I unplugged this loop, the clock returned to normal.
A copy of this log entry has been emailed to: rom,brads,zhaobo,rsubedi