• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name Holmstrom

    Log entry time 12:32:24 on April26,2009

    Entry number 268698

    keyword=Raster on ref. Cell

    After a 90 minute down we did a raster check. We found the follwoing rates:

    2x2 1.2kHz
    4x4 1.2kHz
    5x5 1.3kHz
    6x6 1.4kHz

    After discussing this with Brad we decide to run at 3x3 on the reference cell. Beam is on the desired target range on the whiteboard.