• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name miham

    Log entry time 03:03:17 on April 27, 2009

    Entry number 268947

    keyword=BB threshold Calibration runs

    Today I have taken few calibration runs in order to determine
    correct Threshold settings for the BB trigger.

    Hydrogen runs:

    Run # |E - Threshold|dE-Threshold (TDC) |dE-Threshold(trigger)
    #1515 60 60 120
    #1516 100 100 200
    #1517 150 150 150
    #1518 200 200 200


    Carbon runs:

    Run # |E - Threshold|dE-Threshold (TDC) |dE-Threshold(trigger)
    #1530 100 100 200
    #1531 150 150 300
    #1532 200 200 400
    #1533 300 300 600
    #1534 60 60 60
    #1535 40 40 40



    A copy of this log entry has been emailed to: doug, moffit, sirca, miham