• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name ellie

    Log entry time 15:24:33 on April 29, 2009

    Entry number 269781

    keyword=HAND ADC Filters Changed Positions

    After the HAND move and before run 20563, Bryan and I were working on getting the neutron detector back up and running. As part of this, we moved the ADC filters (as well as found another one in a cabinet that was added) so that the following channels are now the only ones with ADC filters:

    N2-3L through N2-18L (ADC Slot 4, Channels 0 through 16)
    V-17R through V-32R (ADC Slot 5, Channels 17 through 32)
    N1-1R through N1-17R (ADC Slot 5, Channels 32 through 48)
    N2-3R through N2-18R (ADC Slot 6, Channels 0 through 16)
    N2-19R through N3-10R (ADC Slot 6, Channels 17 through 32)
    N3-11R through N4-4R (ADC Slot 6, Channels 32 through 48)