keyword=HAND ADC Filters Changed Positions
After the HAND move and before run 20563, Bryan and I were working on
getting the neutron detector back up and running. As part of this, we
moved the ADC filters (as well as found another one in a cabinet that was
added) so that the following channels are now the only ones with ADC
filters:
N2-3L through N2-18L (ADC Slot 4, Channels 0 through 16)
V-17R through V-32R (ADC Slot 5, Channels 17 through 32)
N1-1R through N1-17R (ADC Slot 5, Channels 32 through 48)
N2-3R through N2-18R (ADC Slot 6, Channels 0 through 16)
N2-19R through N3-10R (ADC Slot 6, Channels 17 through 32)
N3-11R through N4-4R (ADC Slot 6, Channels 32 through 48)