• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 06:44:03 on April 30, 2009

    Entry number 269911

    This entry is a followup to: 269908

    keyword=clarification

    To clarify:

    1. Slow network performance on happex7 might cause deadtime. If you run "pan" and
    see a lot of complaints about "window pairs" and the like. Howerver, this crate doesn't
    produce much data so yu may get lucky even if you have a lousy 4 kbyte/sec network
    performance. I ran pan on a recent run 31294 and saw 4 pair sequence error in
    130K events, about an hour of running. Not too bad.

    2. The work I mentioned on PVDIS crate was done during the shutdown (just to clarify).

    A copy of this log enty has been emailed to: moffit@jlab.org,rsubedi@jlab.org