    User name R. Michaels

    Log entry time 11:18:44 on May 2,2009

    Entry number 270424

    keyword=work on Compton DAQ

    I worked for an hour on Compton DAQ configs:
    
    First of all, the "Production" config was not touched, and the
    present run #16771 was continuing all this time.
    
    I made two new DAQ configs:  Prod_FA and Prod_FT.  The "F" means
    FADC crate is included, and the "A" means accumulator mode, while
    "T" means triggered mode (actually Accumulator-and-Triggered here).
    
    Lib and CRL are in /home/compton/bob/fadc (see README) and are
    compiled with vxWorks 5.5 headers and makelist.local.
    
    I went as far as I could without hallavme8 (ROC6) being up.
    It needs to be power cycled or maybe someone left the power off.
    Need an opportunistic access to fix this, then the first time
    we run these new configs I should be around to check.
    
    Again, "Production" should continue to work like before.